File Management
4-4 File Menu
Site Master User Guide
PN: 10580-00252 Rev. K
4-13
Save On... Menu
Key Sequence:
Shift
>
File
(
7
)
>
Save On Event
In Spectrum Analyzer mode, this menu is used to automatically save
measurements to the current save location after any of the following events:
...Crossing Limit
On Off:
When this submenu key is set to On, measurement data is
automatically saved when the trace crosses a limit line that has been
specified with the Limit menu.
...Sweep Complete
On Off:
When this key is set to On, measurement data is automatically
saved after the current sweep is completed.
Save Then Stop
On Off:
Set this key to On to stop the sweep after a measurement is
saved. If this setting is Off and Sweep Complete is On, a measurement is
saved after every sweep.
Clear All:
Press this key to turn Off all three Save On Event keys:
Crossing Limit
Sweep Complete
Save Then Stop
Back:
Press this key to return to the
.
Figure 4-16.
Save On Menu
Save On...
...Crossing Limit
On Off
...Sweep Complete
On Off
Back
Clear All
Save Then Stop
On Off
Summary of Contents for S331E
Page 2: ......
Page 36: ...2 9 Tilt Bail Stand Instrument Overview 2 22 PN 10580 00252 Rev K Site Master User Guide ...
Page 48: ...3 4 Spectrum Analyzer Quick Start Guide 3 12 PN 10580 00252 Rev K Site Master User Guide ...
Page 82: ...7 1 Overview Bias Tee Option 10 7 2 PN 10580 00252 Rev K Site Master User Guide ...
Page 100: ...A 1 Introduction Measurement Guides A 2 PN 10580 00252 Rev K Site Master User Guide ...
Page 124: ...Index 4 PN 10580 00252 Rev K Site Master User Guide ...
Page 125: ......