Chapter 4 Operations for Each Function
4-108
Note:
The baseband signal synthesizer option is required to use Add
Pattern.
(6) Frequency Offset
Set the output frequency offset for the waveform pattern selected as
an element.
The setting range is as follows:
Fs: Sampling Rate
BW: The maximum modulation bandwidth of the selected element
(defined in the wvi file of each pattern.)
n:
The maximum integer within the range such that Fs*2n does
not exceed 160 MHz.
When Fs ≤ 20 MHz:
(0.8*Fs*2
n
-
BW)
The maximum frequency offset
=
2
When Fs > 20 MHz:
(0.8*Fs
-
BW)
The maximum frequency offset
=
2
(7) Timing Offset
Set the differential delay from the top of the Element1 pattern to the
start of the Add pattern output. The setting unit is one waveform
pattern sample.
Setting range: 0 to “Element1 sample count – 1”
(8) Package
Set the package name to be stored during transfer to the
MG3700A/MG3710A/MG3710E/MG3740A.
(9) Sequence Repeat Mode
When the waveform pattern of the last element registered in the list
is output for the number of times set in Repeat Count, the sequence
processing returns to the waveform pattern of the first element and
is executed repeatedly. End of Sequence (signal with RF output OFF)
is automatically added to the last element registered in the list.
When the waveform pattern of the last element is output for the
number of times set in Repeat Count, an End of Sequence (signal
with RF output OFF) waveform pattern is selected, and the
sequence processing ends without outputting any RF signals. Up to
199 elements can be set, excluding End of Sequence.