6
2.
RJ45 patch cables category 5 that connect the ArcPower 16x6 each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1:
Not used
Pin 1:
Not used
Pin 2:
Not used
Pin 2:
Not used
Pin 3:
Not used
Pin 3:
Not used
Pin 4:
Not used
Pin 4:
Not used
Pin 5:
+5V
Pin 5:
+5V
Pin 6:
Data +
Pin 6:
Data +
Pin 7:
Data -
Pin 7:
Data -
Pin 8:
GND
Pin 8:
GND
5 DMX operation
1.Unplug from the mains before installation.
2.Connect the LED modules to the fixture according to the operation (RGB or RGBW).
3.Connect DMX controller to the fixture
4.Connect the fixture to the mains
5.Set the DMX address on the control board of the fixture (see chapter "Control board").
6.Run internal calibration of the fixture (menu path: SPEC-->CALi--->COMP.)
Warning!
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
network Hub) can damage the ArcPower 16x6.
Maximum total cable length between Arcpower 16x6 and all connected LED modu-
les is 80 metres.
5.1 Single ArcPower 16x6 installation
1. RGB operation
Max. load per LED output zone: 6x1W LED
Number of zones: 16
2. RGBW operation
The ArcPower 16x6 allows to operate 12 RGBW outputs (zones) and it is not necessary to change its menu
setting. You can choose Mode1 for RGBW (up to DMX 48 channels) or Mode2 including the shutter (DMX=
49) and dimmer (DMX= 50) channel - see DMX protocol for RGBW operation.
Note: Only 12 zones of the ArcPower 16x6 can be used for RGBW operation - see chapter 3 "Description
of the ArcPower 16x6"
.