background image

17

8.5 Stand-alone mode

Use this menu to run a program or to set a running program in the stand-alone operation - operation without 

connected DMX controller 

Auto

 --- 

Presetting playback

.This function allows you to select the program which will be played continuously 

in a loop after switching the fixture on.The fixture has four freely-programmable programs (EPG1-EPG4) and 

five built-in programs (PrG1-PrG5).

 

 

OFF

 --- The option disables "Auto" function.

 

 

tSt

 --- The option starts test program

 

 

EPG.1

 --- The option starts editable program No.1

 

 

:

 

 

EPG.4

 --- The option starts editable program No.4

 

 

PrG. 1

 --- The option starts built-in program No.1

 

 

:

 

 

PrG. 5

 --- The option starts built-in program No.5

PLAY

 --- 

Playing program

.Select this menu to run a desired program immediately.

 

 

EPG.1

 --- The option starts editable program No.1

 

 

:

 

 

EPG.4

 --- The option starts editable program No.4

 

 

PrG. 1

 --- The option starts built-in program No.1

 

 

:

 

 

PrG. 5

 --- The option starts built-in program No.5

Select the program you wish and press [ENTER].The selected program starts running.By Pressing [ENTER] 

again is possible to pause the program running.

8.6 Special functions

Use this menu for special  services.

VErS.

 ---

 Software Version

.Select this function to read the number of the fixture software version.

tEmP.

 ---

 Fixture temperature

.This item indicates temperature inside of the ArcPower 16x6.

bALA.

 ---

 Balance

.Select this function to enable (On) or disable (OFF) the white balance which is set in "White 

colour balance" menu below.If this function is set OFF,ArcPower 16x6 will use maximum value (255) of satura

-

tion for red, green and blue channels.

CALi.

 ---

 LED intensity calibration

.The menu allows you to adjust the max. light intensity of individual LEDs 

(colour channels),e.g. the light intensity of all red LEDs connected to the channel 4.This action is suitable in case 

that adjacent LEDs (e.g. in LED array) have a different light intensity (but these LEDs have to be connected to 

the different zones of the ArcPower 16x6).

Use [UP] and [DOWN] buttons to select desired LED,press [ENTER] and adjust suitable light intensity (0-255) 

using  [UP] and [Down] buttons,confirm by pressing [ENTER].This adjusted light intensity is its maximum intensity 

which can be reached if dimmer=255 DMX. After calibration all LEDs, select 

Stor.

 to save adjusted values.

 

COMP

.-  Internal  calibration.The  function  eliminates  random  light  flashes  during  slow  dimming.The 

calibration action lasts cca one minute.

 

The COMP function should be performed:

  

 

- once after connecting all LEDs to the fixture (after complete installation)

 

 

- if the load has been changed (e.g 6-LEDs modules have been replaced by 3-LEDs)

 

 

- after software upgrade or changing dimmer characteristic (SPEC--->CHAr)

C.bAL.

 ---

 White colour balance.

 Using this menu you can set white balance:

1.

 Set all red,green and blue channels on maximum  saturation(255)

2.

  Browse  through  the  menu  by  pressing  the  [UP]  and  [DOWN]  buttons  until  the  display  shows  "

C.bAL

." 

menu.Press  [ENTER] button and 

"rEd.b."

 will appear on the display.

3

.Press [ENTER] button again and use [UP] and [DOWN] buttons to adjust the new maximum value required 

for the red channel.Confirm your choice by pressing [ENTER].Use the [UP] and [Down] buttons to select next 

colour.

Summary of Contents for ArcPower 16x6

Page 1: ...Version 1 1...

Page 2: ...DMX operation 6 5 1 Single ArcPower 16x6 installation 6 5 2 Multiple ArcPower 16x6 installation 7 6 ArcPower 16x6 Control menu map 8 7 ArcPower 16x6 DMX protocol version 1 1 9 8 Control board 15 8 1...

Page 3: ...airs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to...

Page 4: ...C power source from 100 240 Volts Carefully prepare the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be installed following the manufacturer s instructions The...

Page 5: ...are four mounting holes of a diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower 16x6 to...

Page 6: ...see chapter Control board 6 Run internal calibration of the fixture menu path SPEC CALi COMP Warning Accidental connection DMX 512 Input Output to non DMX 512 device e g Ethernet network Hub can dama...

Page 7: ...ArcPower 16x6 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower 16x6 the data link has to be terminated with a terminator A termination plug i...

Page 8: ...F tim 0 255 S tim 0 255 COPY P End 1 60 MAn C rEd 1 0 255 GrE 1 0 255 bLu 1 0 255 Stro 0 255 dimr 0 255 tESt St AL Auto OFF tESt PrG 5 PLAY EPG 1 SPEC PrG 5 VErS tEmP CALi rEd 1 0 255 bL 16 0 255 Stor...

Page 9: ...rtional 11 11 0 255 Green LED 4 Green LED saturation control 0 100 proportional 12 12 0 255 Blue LED 4 Blue LED saturation control 0 100 proportional ZONE 5 13 13 0 255 Red LED 5 Red LED saturation co...

Page 10: ...reen LED 12 Green LED saturation control 0 100 proportional 36 36 0 255 Blue LED 12 Blue LED saturation control 0 100 proportional ZONE 13 37 37 0 255 Red LED 13 Red LED saturation control 0 100 propo...

Page 11: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Page 12: ...255 Blue LED 4 Blue LED saturation control 0 100 proportional 1 1 0 255 White LED 4 Blue LED saturation control 0 100 proportional ZONE 6 16 16 0 255 Red LED 6 Red LED saturation control 0 100 proport...

Page 13: ...5 Blue LED 12 Blue LED saturation control 0 100 proportional 12 12 0 255 White LED 12 Blue LED saturation control 0 100 proportional ZONE 14 40 40 0 255 Red LED 14 Red LED saturation control 0 100 pro...

Page 14: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Page 15: ...ll start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing ENTER After having addressed ArcPower 16x6 you may now start operating ArcPower 16x6 via...

Page 16: ...5 77 2 0 4 55 5 110 20 2 165 45 4 220 80 7 5 2 5 60 6 115 22 170 48 2 225 84 4 10 10 65 7 120 24 175 51 230 88 2 15 22 5 70 8 2 125 26 180 54 235 92 20 40 75 9 4 130 28 2 185 57 240 96 25 62 5 80 10 7...

Page 17: ...FF ArcPower 16x6 will use maximum value 255 of satura tion for red green and blue channels CALi LED intensity calibration The menu allows you to adjust the max light intensity of individual LEDs colou...

Page 18: ...der on your hard disk and download the software to it 3 Unpack the program from the archives Program file has name DSU_name of corresponding fixture_SoftwareID SoftwareID describes the versions of fix...

Page 19: ...s RGBW operation LED zones 12 Max load per zone 8 x 1W LED Total max load 12x8 LEDs Maximum total cable length between one zone of the Arcpower 16x6 and connected LED modules 80 metres at max load DMX...

Page 20: ...e fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 16x6 with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install...

Page 21: ...21...