CAUTION!

Unplug mains lead before opening the housing!

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY 

BEFORE YOU INITIAL START - UP!

1. Safety instructions

Every person involved with installation and maintenance of this product has to:

- be qualilfied

- follow the instructions of this manual

CAUTION!

 Be careful with your operations. With a high voltage  you can suffer

a dangerous electric shock when touching the wires inside the unit!

This product has left our premises in absolutely perfect condition. In order to maintain this condition and to 

ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning 

notes written in this manual.

To prevent from danger of accident ,the device has to be fixed on flat, non-flamma-

ble surface  in compliance with the installing instruction included in this manual.

 

Important:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this 

manual or any unauthorized modification to the product.

Always ground the unit.

The electric connection, repairs and servicing must be carried out by a qualified employee.

Do not connect this unit to a dimmer pack.

Use  a source of AC power that complies with local building and electrical rules.AC power has to have both 

overload and short circuit protection

2. Operating determinations

This product was designed for indoor use only.

If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on 

immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has 

reached room temperature.

Avoid brute force when installing or operating the unit.

When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture 

or dust. 

Only operate the unit after having checked that the housing is firmly closed and all screws are tightly fas

-

tened.

The maximum ambient temperature 40° C must never be exceeded.

Operate the unit only after having familiarized with its functions. Do not permit operation by persons not quali-

fied for operating the unit. Most damages are the result of unprofessional operation!

Please use the original packaging if the product is to be transported.

Please consider that unauthorized modifications on the unit are forbidden due to safety reasons!

Summary of Contents for ArcPower 16x6

Page 1: ...Version 1 1...

Page 2: ...DMX operation 6 5 1 Single ArcPower 16x6 installation 6 5 2 Multiple ArcPower 16x6 installation 7 6 ArcPower 16x6 Control menu map 8 7 ArcPower 16x6 DMX protocol version 1 1 9 8 Control board 15 8 1...

Page 3: ...airs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to...

Page 4: ...C power source from 100 240 Volts Carefully prepare the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be installed following the manufacturer s instructions The...

Page 5: ...are four mounting holes of a diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower 16x6 to...

Page 6: ...see chapter Control board 6 Run internal calibration of the fixture menu path SPEC CALi COMP Warning Accidental connection DMX 512 Input Output to non DMX 512 device e g Ethernet network Hub can dama...

Page 7: ...ArcPower 16x6 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower 16x6 the data link has to be terminated with a terminator A termination plug i...

Page 8: ...F tim 0 255 S tim 0 255 COPY P End 1 60 MAn C rEd 1 0 255 GrE 1 0 255 bLu 1 0 255 Stro 0 255 dimr 0 255 tESt St AL Auto OFF tESt PrG 5 PLAY EPG 1 SPEC PrG 5 VErS tEmP CALi rEd 1 0 255 bL 16 0 255 Stor...

Page 9: ...rtional 11 11 0 255 Green LED 4 Green LED saturation control 0 100 proportional 12 12 0 255 Blue LED 4 Blue LED saturation control 0 100 proportional ZONE 5 13 13 0 255 Red LED 5 Red LED saturation co...

Page 10: ...reen LED 12 Green LED saturation control 0 100 proportional 36 36 0 255 Blue LED 12 Blue LED saturation control 0 100 proportional ZONE 13 37 37 0 255 Red LED 13 Red LED saturation control 0 100 propo...

Page 11: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Page 12: ...255 Blue LED 4 Blue LED saturation control 0 100 proportional 1 1 0 255 White LED 4 Blue LED saturation control 0 100 proportional ZONE 6 16 16 0 255 Red LED 6 Red LED saturation control 0 100 proport...

Page 13: ...5 Blue LED 12 Blue LED saturation control 0 100 proportional 12 12 0 255 White LED 12 Blue LED saturation control 0 100 proportional ZONE 14 40 40 0 255 Red LED 14 Red LED saturation control 0 100 pro...

Page 14: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Page 15: ...ll start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing ENTER After having addressed ArcPower 16x6 you may now start operating ArcPower 16x6 via...

Page 16: ...5 77 2 0 4 55 5 110 20 2 165 45 4 220 80 7 5 2 5 60 6 115 22 170 48 2 225 84 4 10 10 65 7 120 24 175 51 230 88 2 15 22 5 70 8 2 125 26 180 54 235 92 20 40 75 9 4 130 28 2 185 57 240 96 25 62 5 80 10 7...

Page 17: ...FF ArcPower 16x6 will use maximum value 255 of satura tion for red green and blue channels CALi LED intensity calibration The menu allows you to adjust the max light intensity of individual LEDs colou...

Page 18: ...der on your hard disk and download the software to it 3 Unpack the program from the archives Program file has name DSU_name of corresponding fixture_SoftwareID SoftwareID describes the versions of fix...

Page 19: ...s RGBW operation LED zones 12 Max load per zone 8 x 1W LED Total max load 12x8 LEDs Maximum total cable length between one zone of the Arcpower 16x6 and connected LED modules 80 metres at max load DMX...

Page 20: ...e fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 16x6 with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install...

Page 21: ...21...

Reviews: