8
9
Maximum possible number of LED modules connected to the one zone of ArcPower 144:
Model
total
LEDs
Red
LEDs
Green
LEDs
Blue
LEDs
White
LEDs
Max. number of
connected modules
ArcLine 12 RGB
12
4
4
4
-
3
ArcLine 24 RGB
24
8
8
8
-
1
ArcLine 36 RGB
36
12
12
12
-
1
ArcLine Optic 12 RGB
12
4
4
4
-
3
ArcLine Optic 24 RGB
24
8
8
8
-
1
ArcLine Optic 36 RGB
36
12
12
12
-
1
ArcSource 3 RGB
3
1
1
1
-
12
ArcSource 6 RGB
6
2
2
2
-
6
ArcSource 12 RGB
12
4
4
4
-
3
ArcSource 7 RGBW
7
2
2
2
1
6
Note:
You cannot combine RGB and RGBW modules (e.g. ArcSource 6 RGB and ArcSource 7 RGBW)
each other because white LEDs will not light.
5.2 Master-slave operating
1. Unplug from the mains before installation.
2. Connect the LED module to the fixtures.
3. Connect the DMX output of the master fixture in the data-chain with the DMX input of the first slave. Always
connect output with the input of the next slave until all slaves are connected. Up to 32 fixtures can be con-
nected in master/slave chain
4. Insert the termination plug (with 120 Ohm) into DMX input of the master fixture and into the DMX output of the
last slave fixture in the link in order to ensure proper transmission on the data link.
5. Connect the fixtures to the mains.
6. See chapter „Stand-alone mode” in order to set the fixture as a master or slave.