59
2017/08 Rev. 2.0
EN
OptiBean NG /OptiBean XL NG
Service menu continued ...
Main item
Sub-item
Sub
Range
Description
2.7 Hardware test
Inputs
Temp
Boiler temp °C
Shows the status of the sensors/switches
concerned
1
2
3
4
5
6
7
8
9
10
11
12
13 14 15
17
18
1
2
3
4
5
16
Drip tray sensor
yes/no
Waste bin
yes/no
Door switch 1 (pin) yes/no
key switch
yes/no
brewer switch 1 (right) yes/no
brewer switch 2 (left) yes/no
Door switch 2 (lock) yes/no
Key panel
Service panel
Cup sensor left
yes-no
Cup sensor middle yes-no
Cup sensor right
yes-no
Jumper detection
yes-no
Outputs
Test by holding
in recipe button
11.
# During test the
display shows
the Nominal
current (mA).
When the
Nominal
current of a out-
put rises above
the set current *
mentioned output
will be shut off.
KW1
500mA
Inlet valve (Boiler)
DV1
Dispensing valve 1 (Brewer)
DV2
Dispensing valve 2 (Mixer 2)
DV4
Dispensing valve 4 (Hot water)
DV5
Measuring valve 5 (n.a.)
DV6
NO valve
IM1 #
-
Grinder motor 1
IM3 #
600mA
Ingredient motor 3
IM4 #
600mA
Ingredient motor 4
BM #
900mA
Brewer motor
MM2 #
2000mA
Mixer motor 2
Ventilator
-
Fan
LED’s
LED’s
KW2
Pump (via SSR)
KW3
500mA
Valve KW3 cold water
Optilight
Red, Green, Blue
Summary of Contents for optibean ng
Page 1: ...service book Feel like a barista OptiBean NG OptiBean XL NG Model 2016 Reversed brewer...
Page 105: ...105 2017 08 Rev 2 0 EN OptiBean NG OptiBean XL NG...
Page 106: ...106 OptiBean NG OptiBean XL NG 2017 08 Rev 2 0...
Page 107: ...107 2017 08 Rev 2 0 EN OptiBean NG OptiBean XL NG...
Page 108: ...108 OptiBean NG OptiBean XL NG 2017 08 Rev 2 0...