Hoofd item
Sub item
Item
Bereik
Set
Beschrijving
2.4 settings
Language
English
Display language selection.
English is factory set.
Other languages on request
(if available)
Nederlands (Dutch)
Deutsch (German)
Français (French)
Svenska (Swedish)
Norsk (Norwegian)
Suomi (Finnish)
Dansk (Danisch)
Temperature
Temperature boiler
70-97°C *
90°C * Boiler temperature
Temperature hysteresis
0-10°C
0°C
Temperature decrease after which
the boiler must heat up again
Output block
70-80°C
70°C
Boiler temperature at which no
more vending can take place.
Display:
[Out of service, boiler heating]
Output release
80-90°C
80°C
Boiler temperature at which vending
can be released again
Temperatuur stand-by
uit / 60-80°C uit
Boiler temperatuur tijdens stand-by
Display
Show clock
Yes/no
No
Show clock in display
Show date
Yes/no
No
Show date in display
Daylight saving time
Autom saving
time
Yes/no
Yes
Automatic summer time
Summertime
zone
EU/USA zone
EU
Summer time zone
Time differences
+1 / -1 DTS
+1
Time difference
Use beeper
yes-no
yes
Sound signal on or off
Ventilator
Fan time
0-300 sec.
60 s.
Duration of fan speed 2 after
dispensing.
Fan speed 1
40-100%
40%
Fan speed when idle
Fan speed 2
40-100%
70%
Fan speed during dispensing
Summary of Contents for optibean ng
Page 1: ...service book Feel like a barista OptiBean NG OptiBean XL NG Model 2016 Reversed brewer...
Page 105: ...105 2017 08 Rev 2 0 EN OptiBean NG OptiBean XL NG...
Page 106: ...106 OptiBean NG OptiBean XL NG 2017 08 Rev 2 0...
Page 107: ...107 2017 08 Rev 2 0 EN OptiBean NG OptiBean XL NG...
Page 108: ...108 OptiBean NG OptiBean XL NG 2017 08 Rev 2 0...