background image

5000M Crusader G Upgrade Installation Guide

 

 

P/N 70000549B 

 
 

  

 

All rights reserved. Subject to change without notice. 

14-February-03 

Remote Start/Stop (Option) Installation 

Objective: 

‰

 

To install a remote start/stop pushbutton station on the console.  

Tools:

  Small Flat Screwdriver 

Kit: 

Part Number 

Description 

33000122 

Remote start/stop kit, including preassembled pushbutton 
station and a 10-32, 3/8” shoulder bolt, P/N 86100853. 

Procedure: 

 

NOTE:

  You must complete changes to 

Setup Utility

 parameters before 

you can operate the Remote Start/Stop. 

 

To install the Remote Start/Stop (Option): 

1.  Locate the Start/Stop pushbutton station and the shoulder bolt,  

P/N 86100853. 

2.  Remove one of the 10-32, black Phillips-head screws on the right side 

of the console and replace it with the shoulder bolt. 

3.  Plug the remote Start/Stop cable into the back of the console at the 

START

/

STOP

 connector.  Refer to 

Figure 1, Console Rear Panel

4.  Hand-tighten both screws on the connector. 

5.  Mount the pushbutton station on the shoulder bolt. 

Summary of Contents for 5000M

Page 1: ...the following parts 1 One 5000M Console to match your existing Crusader G A7533006 3 Axis Level 1 A7553002 5 Axis Level 2 2 Software Package A4530016 3 Axis Software Package or A4550015 5 Axis Softwar...

Page 2: ...ring connecting the servo to the card cage The Servo Reset are located on the new console and will be disconnected from the existing Servo Cabinet The RS 232 connection is a standard 9 Pin DB computer...

Page 3: ...abel it P6 vi Remove the 110 VAC cable connected to the Power Supply Hot Neutral and Ground c Remove the RS 232 plug from the servo cabinet wall It is directly connected to the card cage and will prev...

Page 4: ...m the PCB 801 P7 connector Replace with the yellow wire from TB3 3 also inserted into a 3 position plug Make sure the yellow wire is on Pin 3 5 Connecting the AC Cable 36000271 to the Interface board...

Page 5: ...iffers from the specifications that follow you will need to modify the Setup Utility in the appropriate sections See the 5000M CNC Setup Utility Manual P N 70000509 for further instructions a Builder...

Page 6: ...ter Parameter tables g Builder Setup General Axis Vector Limits Default is Not Enabled If you have Vector Limits enable them accordingly h Builder Setup Basic I O Interface I O Nodes Can Node 0 Inputs...

Page 7: ...Bit 4 SMT 5 Bit 5 Can Node 2 Outputs Sink SMT 6 Bit 0 SMT 7 Bit 1 S Strobe Bit 2 M Strobe Bit 3 T Strobe Bit 4 k Tuning the system The servo system is ready to be turned on once you have verified the...

Page 8: ...plug located on the back of the console The CNC provides access to network drives via Ethernet Procedure 1 Use a standard CAT5 RJ 45 cable for the network connection Refer to Figure 1 Network Connecti...

Page 9: ...olt P N 86100853 Procedure NOTE You must complete changes to Setup Utility parameters before you can operate the Remote Start Stop To install the Remote Start Stop Option 1 Locate the Start Stop pushb...

Page 10: ...vates Select Ext Start and press ENTER The CNC may prompt for a password If necessary enter the service level password and press ENTER Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Res...

Page 11: ...u D I O Nodes Setup Menu I O Nodes Setup 1 DSP2 Node 2 CAN Node 0 3 CAN Node 1 DSP2 Input 0 Setup Function States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 CAN I O 10 000 Yes Basic I O Interface Se...

Page 12: ...unction States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 Menu E DSP2 Input 0 Setup Menu 1 Off 2 Active Low 3 Active High Menu F Options Setup Menu DSP2 Node Setup 1 Input 0 2 Input 1 3 Input 2 Menu...

Page 13: ...nly Handy Pulser Kit including preassembled Handy Pulser one 10 32 x 3 8 inch shoulder bolt P N 86100853 and mounting bracket P N 23000178 33000965 for 3 4 and 5 axes systems Handy Pulser Kit includin...

Page 14: ...NDWHEEL connector 7 Plug the Handy Pulser cable into the back of the console at the Handwheel connector Refer to Figure 1 Console Rear Panel Figure 5 illustrates the harness handwheel connector Table...

Page 15: ...n these procedures may require you to enter a service level password Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Restricted Parameters To configure the handwheel in the Handy Pulser...

Page 16: ...Menu A Setup Options Menu Setup Options 1 Builder Setup Startup Screen Software Options Menu 2 Setup Utility Software Options Menu D Handwheel DRO 1 Setup Menu Options None Handwheel Linear DRO Rotar...

Page 17: ...ing a keyboard deactivates the console keypad To reactivate the keypad unplug the keyboard The operator cannot activate the E STOP function or reset the servos using an external keyboard These functio...

Page 18: ...mends that you replace the console filter every three months However under some adverse environmental conditions such as oil vapor contamination and or high levels of particulate more frequent filter...

Reviews: