Anilam 5000M Installation Manual Download Page 15

5000M Crusader G Upgrade Installation Guide

 

 

P/N 70000549B 

 
 

  

 

All rights reserved. Subject to change without notice. 

15 

14-February-03 

  

Setup Utility Navigation 

NOTE:

  If you purchased your Handy Pulser separately from the CNC, 

you must configure 

Setup Utility

 parameters before operating 

the Handy Pulser.  If you purchased your Handy Pulser with the 
CNC, 

Setup Utility

 parameters are already configured, and you 

only need to mount the Handy Pulser. 

The 

Setup Utility

 provides access to all CNC settings through a layered 

organization of menus.  Each menu contains a list and provides access to 
configuration settings or another menu.  To select a listed choice, 
highlight the selection.  Press 

ENTER

 to activate the highlighted selection.  

For some settings, press 

ENTER

 to toggle the setting 

On

 or 

Off

.  Other 

settings require you to enter a specific value.  To automatically save a 
highlighted setting, press 

ENTER

 or press 

Exit 

(

F10

).  To return to a 

previous menu, close the current menu by pressing 

F10

  

Handy Pulser Setup 

 

NOTE:

  Some steps in these procedures may require you to enter a 

service-level password.  Refer to 

5000M CNC Setup Utility 

Manual

, P/N 70000509, “Password Restricted Parameters.” 

 

To configure the handwheel in the Handy Pulser:  
1. Refer to 

Figure 6, 5000M Handy Pulser Setup Menus

.  In Manual 

Mode or Power-Up Mode, press 

EXIT

 (

F10

) to display the 

Software 

Options Menu

2. In the 

Software Options Menu

, highlight 

Setup Utility

, and press 

ENTER

.  The 

Setup Options Menu, Menu A

, is displayed. 

3. Highlight 

Builder Setup

, and press 

ENTER

4. In the 

Builder Setup Menu

, highlight 

Handwheel/DRO

, and press 

ENTER

.  The 

Handwheel/DRO Setup Menu, Menu C

, is displayed. 

5. Highlight 

Handwheel/DRO #1

, and press 

ENTER

.  The 

Handwheel 

DRO #1 Setup Menu, Menu D

, is displayed. 

6. Verify that 

Type

 is set to 

Handwheel

.  If necessary, press 

ENTER

 to 

display the 

Options

 popup menu, and select 

Handwheel

7. Highlight 

Handwheel

 in the 

Handwheel DRO #1 Setup Menu

, and 

press 

ENTER

.  The 

Handwheel Setup Menu, Menu E

, is displayed. 

8. Highlight 

Scaling Factor

, and press 

ENTER

9. Type the 

Scaling Factor

 (usually 1.00), and press 

ENTER

10. Press 

EXIT

 (

F10

) successively until the 

Save Changes?

 prompt is 

displayed in the middle of the screen. 

11. Select 

Yes

 (

F1

) to save the changes. 

The handwheel is now ready for use. 

Summary of Contents for 5000M

Page 1: ...the following parts 1 One 5000M Console to match your existing Crusader G A7533006 3 Axis Level 1 A7553002 5 Axis Level 2 2 Software Package A4530016 3 Axis Software Package or A4550015 5 Axis Softwar...

Page 2: ...ring connecting the servo to the card cage The Servo Reset are located on the new console and will be disconnected from the existing Servo Cabinet The RS 232 connection is a standard 9 Pin DB computer...

Page 3: ...abel it P6 vi Remove the 110 VAC cable connected to the Power Supply Hot Neutral and Ground c Remove the RS 232 plug from the servo cabinet wall It is directly connected to the card cage and will prev...

Page 4: ...m the PCB 801 P7 connector Replace with the yellow wire from TB3 3 also inserted into a 3 position plug Make sure the yellow wire is on Pin 3 5 Connecting the AC Cable 36000271 to the Interface board...

Page 5: ...iffers from the specifications that follow you will need to modify the Setup Utility in the appropriate sections See the 5000M CNC Setup Utility Manual P N 70000509 for further instructions a Builder...

Page 6: ...ter Parameter tables g Builder Setup General Axis Vector Limits Default is Not Enabled If you have Vector Limits enable them accordingly h Builder Setup Basic I O Interface I O Nodes Can Node 0 Inputs...

Page 7: ...Bit 4 SMT 5 Bit 5 Can Node 2 Outputs Sink SMT 6 Bit 0 SMT 7 Bit 1 S Strobe Bit 2 M Strobe Bit 3 T Strobe Bit 4 k Tuning the system The servo system is ready to be turned on once you have verified the...

Page 8: ...plug located on the back of the console The CNC provides access to network drives via Ethernet Procedure 1 Use a standard CAT5 RJ 45 cable for the network connection Refer to Figure 1 Network Connecti...

Page 9: ...olt P N 86100853 Procedure NOTE You must complete changes to Setup Utility parameters before you can operate the Remote Start Stop To install the Remote Start Stop Option 1 Locate the Start Stop pushb...

Page 10: ...vates Select Ext Start and press ENTER The CNC may prompt for a password If necessary enter the service level password and press ENTER Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Res...

Page 11: ...u D I O Nodes Setup Menu I O Nodes Setup 1 DSP2 Node 2 CAN Node 0 3 CAN Node 1 DSP2 Input 0 Setup Function States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 CAN I O 10 000 Yes Basic I O Interface Se...

Page 12: ...unction States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 Menu E DSP2 Input 0 Setup Menu 1 Off 2 Active Low 3 Active High Menu F Options Setup Menu DSP2 Node Setup 1 Input 0 2 Input 1 3 Input 2 Menu...

Page 13: ...nly Handy Pulser Kit including preassembled Handy Pulser one 10 32 x 3 8 inch shoulder bolt P N 86100853 and mounting bracket P N 23000178 33000965 for 3 4 and 5 axes systems Handy Pulser Kit includin...

Page 14: ...NDWHEEL connector 7 Plug the Handy Pulser cable into the back of the console at the Handwheel connector Refer to Figure 1 Console Rear Panel Figure 5 illustrates the harness handwheel connector Table...

Page 15: ...n these procedures may require you to enter a service level password Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Restricted Parameters To configure the handwheel in the Handy Pulser...