ELECTRICAL CONNECTION
Important
Those authorised to carry out the connection
operation must have experience acquired and
certifi ed in the specifi c sector, in accordance
with current legislation in the appliance’s in-
stallation country.
The connection must make to the proper
standards and must comply with all the rele-
vant regulations and legislation.
The appliance is supplied with operating volt-
age 230V/1N 50Hz ( Selector switch allowed
60Hz, see electrical system diagram).
Caution - Warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity
supply as follows:
1)
If not already present, install an automatic
circuit-breaker
(A)
, close to the appliance, with
the following characteristics:
– Thermal breaker device (to adjust see table
Annexes).
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at mA 30.
2)
Open the hatch
(B)
.
3)
Undo the screws to remove the drain lever
(C)
.
4)
Undo the screws to remove the pane
(D)
.
5)
Connect the circuit-breaker
(A)
to the terminal
board
(G)
of the appliance as shown in the
diagram and in the electrical system diagram
at the back of the manual. Use a cable with at
least H05RN-F characteristics. Tighten the cable
gland (
H).
– Weight: ≥ than H05RN-F type (designation 245
IEC 57)
– Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
6)
Tighten the cable gland
(H)
.
7)
Replace all when the operation is complete.