C13143
040.
fm
- 11 -
English
I
T
GB
D
E
FR
E
S
The appliance has been tested before being put into
service.
The information provided below is intended to assist
in the identification and correction of any anomalies
and malfunctions which might occur during use.
The user can solve some of these problems himself,
but for others specific technical knowledge or skill is
required, and so they must only be carried out by
qualified staff with recognised experience acquired
in the specific sector of operation.
FAULT
6
TROUBLESHOOTING
Fault
Cause
Remedy
The heating elements do
not come on
Electrical connection not made
correctly
Check the connection of the electrical
wires
Safety thermostat tripped
Carry out the appliance reset
(see page 9)
Switch faulty
Replace the switch
Contact the after-sales service
When the water control
knob is turned to 2
(automatic rapid filling),
water is supplied
continuously, until it
overflows
Blockage in pressure switch circuit
Clean the circuit
Contact the after-sales
service
Pressure switch faulty
Replace the pressure switch
Contact the after-sales service
Filler solenoid valve faulty
Replace solenoid valve
Contact the after-sales service
When the water control knob is
turned to 2 (automatic rapid filling),
no water comes out of the tap
Pressure switch connection not made
correctly
Check the pressure switch
connection
Contact the after-sales service
Water connection not made correctly
Check the water connection
Contact the after-sales service
When the water control knob is
turned to 3 (automatic slow filling),
slow filling does not take place
Water level maintenance solenoid
valve connection not made correctly
Check the solenoid valve
connection
Contact the after-sales service
Water level maintenance solenoid
valve faulty
Replace solenoid valve
Contact the after-sales service