MDM/992043/10/120121 

Page 15 

period  of  one  year  from  the  date  of  purchase  from  Anetic  Aid  Ltd  or  their  approved 
Distributor.  Anetic  Aid  Ltd  will  repair  or  replace,  at  their  discretion,  any  components 
found to be defective or at variance with the manufacturer’s specification within this time 
at  no  cost  to  the  purchaser.  The  warranty  will  take  effect  from  the  date  of  purchase, 
subject  to the purchaser registering the product  with  Anetic Aid to confirm  its receipt, 
installation date and product details. 

 

The warranty does not provide cover for breakage or failure due to tampering, misuse, 
neglect, accidents, modifications or shipping. The warranty is also void if the product is 
not  used  in  accordance  with  the  manufacturer’s  instructions  or  is  repaired  during  the 
warranty period by any persons other than Anetic Aid or its appointed agent. No other 
expressed or implied warranty is given. 

 

For  details  of  our  extended  warranty  packages  please  contact  Anetic  Aid  or  your 
authorised dealer. 

14.

 

Disposal of Waste Electrical & Electronic Equipment  

  

This  symbol  on  the  products  and/or  accompanying  documents  means 
that  used  electrical  and  electronic  products  should  not  be  mixed  with 
general waste. 
 
Disposing  of  this  product  correctly  will  save  valuable  resources  and 
prevent  any  potential  negative  effects  on  human  health  and  the 
environment  which  could  otherwise  arise  from  inappropriate  waste 

handling.  If you are unsure of your national requirements with respect to disposal please 
contact your local authority, dealer or supplier for further information.  

 

Penalties  may  be  applicable  for  incorrect  disposal  of  this  waste,  in  accordance  with 
national legislation. The above information is based on the European waste electrical and 
electronic  equipment  directive  2002/96/EC.  Please  note  the  electrically  powered  AT4 
contains a lead acid battery pack which will require to be replaced every two years. 

 

Summary of Contents for 40080

Page 1: ......

Page 2: ......

Page 3: ...Warnings Cautions and Side effects 2 3 Symbols 3 4 Getting Started 5 4 1 Fitting the Fuse and Charging the Battery 5 4 2 Connecting and Storing the Cuff Hoses 5 5 Product Functions 6 6 Controls and O...

Page 4: ...is intended for the control of pneumatic tourniquet cuffs in operating theatres or similar environments 1 2 Intended user Tourniquets should only be operated by trained and competent clinical staff a...

Page 5: ...n accordance with the manufacturer s guidelines see Section 9 CAUTIONS Before use ensure all device functions operate correctly Also visually inspect the device for any loose or damaged parts If the d...

Page 6: ...ational Red indicates incorrect action TIMER REMINDER Prior to inflation of cuff this button sets the reminder start time and repeater frequency This function is cancelled after the cuff has been infl...

Page 7: ...TION Maximum power consumption in watts SN SERIAL NUMBER Unique serial number used for traceability REF REFERENCE NUMBER Reference or model number indicating the type of unit DATE OF MANUFACTURE MANUF...

Page 8: ...y the fuse symbol on the underside of the AT4 On receipt or after periods of storage the AT4 must be connected to the mains electricity supply with the cable provided for 24 hours to allow the battery...

Page 9: ...5 Product Functions 1 Control Panel 2 Cuff Supply Hose Storage Connectors 3 Cuff Supply Hose Connectors 4 Cuff Supply Hose 5 Pulling Handle 6 Cuff Hooks 7 Storage Facility 8 Additional Storage Facilit...

Page 10: ...charged and the battery indicator is green if not it must be used connected to the mains supply The red and blue cuff hoses should be connected to the connectors in the front of the AT4 ready for use...

Page 11: ...rotating the control clockwise to increase and anticlockwise to decrease The selected pressure in mmHg is displayed in the window above the rotary control Application of a tourniquet cuff at excessive...

Page 12: ...associated with the pressure set in the previous step If this button is depressed prior to setting the pressure levels above the device will lock out To reset turn the IVRA button off and then back on...

Page 13: ...e Battery Charging Section 9 When the electronic unit is being used while connected to the mains supply Green Amber Alternating Green Amber indicating connection to the mains while in use NOTE The amb...

Page 14: ...result in damage 8 Performance and Technical Specification Accuracy and Resolution Pressure is measured to an accuracy of 2 5 mmHg and displayed with a resolution of 5 mmHg Maximum Cuff Pressure The...

Page 15: ...ssible The AT4 Tourniquet is suitable for use in hospital operating rooms and other clinical areas with antistatic flooring The emissions characteristics of this equipment make it suitable for use in...

Page 16: ...t is recommended that when not in use the device is connected to the mains electrical supply to recharge the battery The battery will not be damaged by leaving it connected to the mains when fully cha...

Page 17: ...indicator of the electrically powered AT4 shows amber connect it to the mains electrical supply as soon as possible If the indicator shows red connect to the mains electrical supply immediately Green...

Page 18: ...er expressed or implied warranty is given For details of our extended warranty packages please contact Anetic Aid or your authorised dealer 14 Disposal of Waste Electrical Electronic Equipment This sy...

Page 19: ...This page has been left blank MDM 992043 10 120121...