7
W-200
HIGH T.E.C. Series_ PRESSURE | SUCTION
EN
WHERE TO INSPECT
REPLACEMENT PART
Each hole passage of air cap set (1) and fluid nozzle set (2-1).
Replace air cap or fluid nozzle if they are crushed or deformed.
Packings and O'rings.
Replace if deformed or worn out.
Leakage from seat section between fluid nozzle (2-1) and fluid
needle set (2-2).
Replace them if leakage does not stop after fully cleaning fluid
nozzle (2-1) and fluid needle set (2-2).
If you replace fluid nozzle (2-1) or fluid needle set (2-2) only, fully
match them and confirm that there is no leakage.
8.1 INSPECTION AND REPLACEMENT STANDARD
9. SPARE PARTS LIST
4
2-1
1
17
16
15
14
5-1
12
11
2-2
8
9
10
7
7-1
13
6
18
19
14-1
G1/4”M
NPSM 1/4”F
W-200 S18
W-200 S25
G1/4”M
G1/4”M
W-2003
Ref.
DESCRIPTION
Model
1
AIR CAP SET
ALL MODELS
2-1
FLUID NOZZLE SET
n
2-2
FLUID NEEDLE SET
4
NEEDLE PACKING SET
n
5-1
AIR NIPPLE
5-2
FLUID NIPPLE
6
PATTERN ADJUSTMENT SET
7
AIR VALVE SEAT
7-1
'O' RING
n
8
AIR VALVE
n
9
AIR VALVE SPRING
10
FLUID ADJUSTMENT GUIDE SET
11
NEEDLE SPRING SET
12
FLUID ADJUSTMENT KNOB
13
AIR VALVE SHAFT
n
14
AIR ADJUSTMENT SET
14-1
PLUG
W-200 S18 | S25
15
TRIGGER STUD
ALL MODELS
16
TRIGGER SET
17
E STOPPER
18
BRUSH
19
UNIVERSAL SPANNER
Models
Fluid Nozzle
Fluid needle
Size
mm (inch)
Mark
Mark
W-200
0.8 (0.031)
W200 /08
20012 H
1.0 (0.039)
W200 /10
20012 H
1.2 (0.047)
W200 /12
20012 H
1.4 (0.055)
W200 /14
20015
1.5 (0.059)
W200 /15
20015
1.8 (0.071)
W200 /18
20020
2.0 (0.079)
W200 /20
20020
2.5 (0.100)
W200 /25
20025
W-200 WB
0.8 (0.031)
200WB /08
40012
1.0 (0.039)
200WB /10
40012
1.2 (0.047)
200WB /12
40012
1.6 (0.063)
400WB /16
20015
1.8 (0.071)
400WB /18
20020
W-200 ZP
1.5 (0.059)
W200 /15Z
NON MARK
(common parts)
2.0 (0.079)
W200 /20Z
2.5 (0.100)
W200 /25Z
W-200 ZP
S18 | -S25
1.0 (0.039)
W200 /10
20010
W-2003
2.0 (0.079)
W200 /20
20020
2.5 (0.100)
W200 /25
20025
NOZZLE AND NEEDLE SET COMBINATION
NEVER REMOVE FLUID NIPPLE FROM GUN BODY! Any malfunc-
tions resulting by the removal of the following parts will not be
covered by the Warranty. In case of replacement contact your
Technical Service directly.
When ordering parts, specify gun model, part name with No.
and marked No. of air cap set, fluid nozzle and fluid needle.