4
EN
W-200
HIGH T.E.C. Series_ PRESSURE | SUCTION
WARNING
FIRE AND EXPLOSION HAZARDS
SPARKS AND OPEN FLAMES ARE STRICTLY PROHIBITED
Paints can be highly flammable and can cause fire.
Do not expose to open flames, electrical goods, cigarettes etc.
SECURELY GROUND SPRAY GUN BY USING A CONDUCTIVE AIR HOSE.
ELECTRICAL RESISTENCE: <1MΩ.
ALWAYS ensure that the spray gun is earthed correctly.
Insufficient grounding can cause fire and explosion due to static electric sparking.
NEVER USE THE FOLLOWING HALOGENATED HYDROCARBON SOLVENTS which can cause cracks or
dissolution on gun body (aluminium) by chemical reaction.
UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 1.2-dichloroethane,carbon tetrachloride,
trichloroethylene, 1.1.1-trichloroethane.
BE SURE THAT ALL FLUIDS AND SOLVENTS ARE COMPATIBLE WITH GUN PARTS.
3. SAFETY WARNING
WARNING
IMPROPER USE OF THE EQUIPMENT
NEVER EXCEED MAXIMUM OPERATING PRESSURE AND MAXIMUM OPERATING TEMPERATURE.
Use at more than max. operating pressure can cause explosion of Spray Gun resulting in great danger.
ALWAYS RELEASE AIR AND FLUID PRESSURE BEFORE CLEANING, DISASSEMBLING OR SERVICING.
Otherwise, remaining pressure can cause bodily injury due to improper operation or scattering cleaning
liquid.
NEVER POINT
Spray Gun towards people or animals.
TIP OF FLUID NEEDLE SET HAS A SHARP POINT.
Do not touch the tip during maintenance to avoid accidents.
NEVER USE THIS GUN TO SPRAY FOODS OR CHEMICALS.
Otherwise, foreign substance, could cause
corrosion of fluid passages which could adversely affect health.
NEVER ALTER THIS SPRAY GUN.
If done, it can cause insufficient performance and failure or in extreme cases, explosions.
WARNING
OTHER PRECAUTIONS
SECURELY CONNECT FLUID HOSE.
If hose is disconnected during operation, hazardous hose movement
and paint ejection will cause severe bodily injury.
IF SOMETHING GOES WRONG, IMMEDIATELY STOP OPERATION AND FIND THE CAUSE.
Do not use again
until you have solved the problem.
NEVER USE SPARE PARTS THAT ARE NOT ANEST IWATA ORIGINALS.
USE NEUTRAL CLEANER:
pH value shall be 6 to 8, otherwise could cause corrosion.
WARNING
PROTECTION OF HUMAN BODY
USE IN A WELL-VENTILATED SITE BY USING A SPRAY BOOTH.
If not, poor ventilation can cause organic solvent poisoning and catch fire. If you feel any abnormality
during operation, consult a medical doctor immediately.
ALWAYS WEAR PROTECTIVE GEAR (safety glasses, mask, gloves.)
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
In case of any physical discomfort for skin or eyes, immediately seek a medical advice.
WEAR EARPLUGS IF NECESSARY.
Noise level can exceed 85 dB(A), depending on operating conditions and painting site.
NEVER TRY TO STOP LEAKS BY HAND, WHEN PAINT LEAKS.
In case of leaks, stop pump immediately and reduce paint pressure down to 0 pressure.
If you feel any abnormality or receive any injury, consult a medical doctor immediately.
Pulling trigger many times during operation, may cause carpal tunnel syndrome.
ALWAYS REST, IN CASE OF TIREDNESS.
Summary of Contents for W 200
Page 38: ...38 Comments...
Page 39: ...39 Comments...