Anemoment LLC
39
Data Logger 422 User Manual
disable - disable the serial port from receiving data from a serial instrument.
baud -
show or set the baud rate of the serial port
<baud> - must be a valid standard serial baud rate.
now - apply the change immediately, otherwise it is applied on the
next reboot
parity - show or set the parity of the serial port
none - set no parity
odd - set odd parity
even - set even parity
now - apply the change immediately, otherwise it is applied on the
next reboot
gps -
configure the reception of data on the serial port to process GPS
sentences and output GPS data in lines with other serial data.
enable – turn on GPS processing
disable – turn off GPS processing
tagged - enable the serial channel tag for this port
untagged - disable the serial channel tag for this port
tag -
use <arg> as the tag for this serial channel port
setdate
Set the Data Logger date
This command sets the date for the Data Logger
<date> - YY/MM/DD
gps -
Set Time and Date with the next GPS update
GPS must be providing valid time data.
settime
Set the Data Logger time
This command sets the time for the Data Logger
<time> - HH:MM:SS Must use 24 hour format.
gps -
Set Time and Date with the next GPS update
GPS must be providing valid time data.
station
Station Tag
station
[enable|disable|tagged|untagged|tag <arg>]
Show or set the Station Tag Value.
enable - enable the station tag display. Also executes the tagged function.
disable - disable the station tag display. Also executes the untagged function.
enable - turns on the station tag display. Also executes the enable function.
disable - turns off the station tag display. Also executes the disable function.
tag -
use <arg> as the station tag.
systemreset
Software Reset.
time
Show the current date and time.
timetag
Show or set the timetag
configuration
. Use "help timetag" for full argument list.
timetag
[enable|disable|dst [enable|disable]|showms [enable|disable]]
timetag
with no arguments displays the current timetag settings.
enable - enable the timetag output in each line of output
disable - disable the timetag output
showms - enable or disable the display of timetag millisecond resolution
enable - enable millisecond display.
disable - disable millisecond display.
trigger
Show or set the trigger
configuration
.
trigger
[serial <rate>|analog <rate>|type <internal|sync|external>|source 1|2]
Show or set the Sampling Rage.
serial -
Set the Sampling Rate in mS
<rate> = mS between samples.
analog - Set the Sampling Rate for the Analog Inputs in mS