12
5. Charge the gear unit with oil or top it up with reference to the method in which gear units of the type co-
vered by this manual are filled in the factory. The standard charge of synthetic life-time lubricant is as fol-
lows:
(A1)
Life-time lubrication.
Life-time lubrication with ATEX-specified unit only.
Cap/vent thread
Pitch
Tightening torque
[Nm]
1/8"
28
5
1/4"
19
7
3/8"
19
7
1/2"
14
14
3/4"
14
14
1"
11
25
Bolt size
Tightening torque [Nm]
+5% /-10%
Bolt class
8.8
10.9
M4
3
3.8
M5
5.9
8.0
M6
10.3
13.0
M825.5
32
M10
50
64
M12
87.3
110
M14
138.3
180
M16
210.9
275
M18306
390
M20
432
540
M22
592
720
M24
744
930
M27
1100
1400
M30
1500
1850
(A0)
C 05
C 11
C 21
C 31
C 35
C 41
C 51
C 61
C 70
C 80
C 90
C 100
A 05
A 10
A 20
A 30
A 35
A 41
A 50
A 55
A 60
A 70
A 8 0
A 90
F 10
F 20
F 30
F 40
F 50
F 60
F 70
F 8
0
F
90
S 10
S 20
S 30
S 40
S 50
VF 27
VF 30
VF 44
VF 49 VF 130 VF 150 VF 185 VF 210 VF 250
W 63
W 75
W 86
W 110
Luggage Point STP ST18 Pre Treatment (Aqua-Screen (Andritz) Operation and Maintenance Manual) General