background image

  DN:KD-5985-SMSY01 V3.0                                                            Operation Guide

 

 

  

 

 

 

 

Template version:1 

6/22                                                   

 

14. 

The  monitor  might  not  meet  its  performance  specifications  or  cause  safety  hazard  if 

stored or used outside the specified temperature and humidity ranges in specifications. 

15. 

Please do not share the cuff with other infective person to avoid cross-infection. 

16.  The  AC  adapter  which  output  is  DC  6.0V,  800mA  and  complied  with  IEC  60601-1/EN 

60601-1/UL  60601-1  and  IEC  60601-1-2/EN  60601-1-2/UL  60601-1-2  is  suitable  for  this 

monitor, we suggest use ASP5-06008002EU (input: 100-240V, 50/60Hz, 200mA; output: 

DC 6V, 800mA) or ASP5-

 06008003UK

 (input: 100-240V, 50/60Hz, 200mA; output: DC 

6V,  800mA)  which  are  complied  with  IEC  60601-1/EN  60601-1/UL  60601-1  and  IEC 

60601-1-2/EN  60601-1-2/UL  60601-1-2,  if  use  the  monitor  with AC  adapter  in  USA,  use 

only ASP5-06008002JU(input: 100-240V, 50/60Hz, 200mA; output: DC 6V, 800mA) which 

is  complied  with  IEC  60601-1/EN  60601-1/UL  60601-1  and  IEC  60601-1-2/EN 

60601-1-2/UL  60601-1-2.  Other  adapters  not  approved  for  use  with  the  monitor  may 
damage  it.  Please  note  that  the  monitor  jack  size:  hole  Φ5.5mm,  center  pin  Φ2.0mm. 

Please pay attention to polarity.   

17.  This  blood  pressure  monitor  is  verified  by  auscultatory  method.  It  is  recommended  that 

you check annex B of ANSI/AAMI SP-10:2002+A1:2003+A2:2006 for details of verification 

method if you need. 

18.  This equipment has been tested and found to comply with the limits for a Class B digital 

device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 

reasonable  protection  against  harmful  interference  in  a  residential  installation.  This 

equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed 

and  used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio 

communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a 

particular  installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or 

television  reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the 

user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the  following 

measures: 

—Reorient or relocate the receiving antenna. 
—Increase the separation between the equipment and receiver. 

—Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected. 

—Consult the dealer or an experienced radio/TV technician for help. 

 

 

SETUP AND OPERATING PROCEDURES 

 

 

1.  BATTERY LOADING AND AC ADAPTER 

LOADING 

 

a.  Open battery cover at the back of the monitor.         

b. 

Load  four  ―AA‖  size  batteries.  Please  pay  attention  to 

polarity. 

c.  Close the battery cover. 

Summary of Contents for KD-5985

Page 1: ...ER LOADING 6 2 SETTING 7 2 1 ALARM SETTING 7 2 2 VOICE SETTING 8 2 3 CLOCK AND DATE ADJUSTMENT 8 2 4 RCC Radio Controlled Clock 9 3 CONNECTING THE CUFF TO THE MONITOR 9 4 APPLYING THE CUFF 10 5 BODY P...

Page 2: ...hest value usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most people are a...

Page 3: ...rate can be measured automatically and non invasively The LCD display will show blood pressure and pulse rate The most recent 2 60 measurements can be stored in the memory with date and time stamp Th...

Page 4: ...0mm 81mm approximate 8 7 3 32 3 3 16 5 Cuff circumference 22cm 30cm 8 21 32 11 13 16 30cm 42cm 11 13 16 16 17 32 Optional 42cm 48cm 16 17 32 18 29 32 Optional 6 Weight about 626g approximate 22 3 32oz...

Page 5: ...hould never be used on infants or young children Consult your physician or other health care professionals before use on older children 9 Do not use this unit in a moving vehicle This may result in er...

Page 6: ...d It is recommended that you check annex B of ANSI AAMI SP 10 2002 A1 2003 A2 2006 for details of verification method if you need 18 This equipment has been tested and found to comply with the limits...

Page 7: ...ther adapters not approved for use with the monitor may damage it The monitor the batteries and the cuff must be disposed of according to local regulations at the end of their usage 2 SETTING a Once y...

Page 8: ...nguage circularly see picture 4 L0 represents closing voice function L1 represents language 1 L2 represents language 2 L7 represents language 7 You can select the wanted language by press the button A...

Page 9: ...pressing START button b Forced RCC Receiving When the monitor working in the SETTING mode and the RCC symbol is blinking press the SET button will enter forced RCC mode and the RCC symbol is twinkling...

Page 10: ...ence range in SPECIFICATIONS to make sure that the appropriate cuff is used Measuring on same arm each time Do not move your arm body or the monitor and do not move the rubber tube during measurement...

Page 11: ...ime if no memory stored in the selected bank c If the voice function is switched on the monitor will speak out measurement tips d Then the monitor inflates the cuff until sufficient pressure has built...

Page 12: ...of the last 7 days is displayed press the MEM button the most recent result will be displayed Press A button to review the next result Press B button to review the front result In this way repeatedly...

Page 13: ...re and humidity automatically every other about five second And the temperature will display with Celsius or Fahrenheit by turns The monitor can t be used as a thermometer or a hygrometer b The LCD ba...

Page 14: ...ate version 1 14 22 It is not intended to provide a basis of any type of rush toward emergency conditions diagnosis based on the color scheme and that the color scheme is meant only to discriminate be...

Page 15: ...N LCD Display shows abnormal result The cuff position was not correct or it was not properly tightened Apply the cuff correctly and try again Body posture was not correct during testing Review the BOD...

Page 16: ...ct the local distributor or the factory LCD shows Er 6 More than 160 seconds with cuff pressure above 15 mmHg LCD shows Er 7 EEPROM accessing error LCD shows Er 8 Device parameter checking error LCD s...

Page 17: ...appropriately qualified technical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for...

Page 18: ...declaration electromagnetic emissions The KD 5985 is intended for use in the electromagnetic environment specified below The customer or the user of the KD 5985 should assure that it is used in such...

Page 19: ...000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV...

Page 20: ...ectromagnetic immunity The KD 5985 is intended for use in the electromagnetic environment specified below The customer or the user of the KD 5985 should assure that it is used in such an environment I...

Page 21: ...agnetic site survey should be considered If the measured field strength in the location in which the KD 5985 is used exceeds the applicable RF compliance level above the KD 5985 should be observed to...

Page 22: ...e determined using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1...