![AND AD-4406 OP-04 Instruction Manual Download Page 36](http://html1.mh-extra.com/html/and/ad-4406-op-04/ad-4406-op-04_instruction-manual_2941308036.webp)
Page
34
AD-4406 Weighing Indicator
Output of Accumulated Data
The accumulated data can be output to the serial interface.
Output by manual or automatic, and output data format is selected at F41 of the
F-function setting.
F41
Parameter
Manual/Automatic Format
0 No
output
* 1
Manual (initial
setting)
2 Automatic
Fixed format
3 Manual
4 Automatic
Format 1 (selected at F34)
5 Manual
Accumulated data
output at
accumulated data
display
6 Automatic
Format 2 (selected at F35)
Step 1 Press the key assigned to operate the function to display totAL and the
accumulated data.
Step 2 If automatic output is set, the data is output once at that timing.
Step 3 If manual output, by pressing the F2 key while the accumulated data is displayed,
the data is output.
Fixed data format :
9. Accumulation