AMD5x Passive Infeed Unit and AMD5x Servo Drive - User Guide
ANCA MOTION
D-000129 Rev 09
68
Motor Circuit Contactors
5.6.1
A motor circuit contactor may be installed if required by local codes or for safety reasons. The motor circuit
contactor isolates the motor fully from the Drive to allow maintenance and may form part of a safety system.
If a contactor is employed in this way, it is essential that measures be taken to ensure that the contactor is not
commanded to open or close whilst the Drive is enabled. One way to achieve this is to employ the same PLC
that enables the Drive to be in control of the contactor via a control relay.
Ensure that shielding of the motor cable is continued on both sides of the motor circuit contactor.
Shielded Armature Cable Schematic
5.6.2
Shielded armature cable schematic for Beta and Gamma Motors is shown in
identification. K5B-ASMD cable variant catalogue numbers can be found in
11.8.2 Shielded Armature Cable for
Figure 5-8: K5B-ASMD schematic and connector pin identification
Shielded Armature Cable with Thermal Sensor for LinX Motor Schematic
5.6.3
Shielded armature cable with thermal sensor schematic for LinX Motors is shown in
identification. K5B-T1MD cable variant catalogue numbers can be found in
11.8.8 Shielded Armature Cables for
Figure 5-9: K5M-T1MD schematic and connector pin identification