13
12
Specifications
Input
Nominal Voltage
110 and 220 VAC (Auto-switching)
Actual Voltage
90 - 133 VAC and 180 -
264
VAC
Current
13.1 A (Maximum @ 90 VAC in)
Fuse
MDA 25 Amp
Input Frequency
49 - 405 Hz
Noise on Input
< 50 mV Peak to Peak
Inrush Current
< 13A @
264
VAC In from fully discharged
Output
Nominal Voltage
12 VDC
24 VDC
32 VDC
36 VDC
48 VDC
72 (Rail) VDC
Actual Voltage
13.6 VDC
27.2 VDC
36.3 VDC
40.8 VDC
54.4 VDC
72.5 VDC
Overvoltage Protection Crowbar 17.0 ±0.5V
34.0 ±1.0V
45.0 ±1.5V
51.0 ±1.5V
68.0 ±2.0V
90.0 ±2.5V
Continuous Amps
80 A
40 A
30 A
27A
20 A
15 A
Peak Amps
120 A
66 A
50 A
45A
33 A
24 A
Fuses
3x ATM30
2x ATM25
2x ATM20
2x 20A Bel
0697H9200
2x 15A Bel
0697H9150
1x 20A Bel
0697H9200
Output Voltage Adjustment
± 1.0 V
Duty Cycle
Continuous: 100% for 24 hours per day
Peak: 20% for ten minutes per hour maximum
Transient Response
<1V for 50% Surge
Ripple and Noise
<50 mV
Efficiency
>85% @ Maximum Output
Noise on Output
< 50 mV
Regulation (Line and Load)
<+/- 0.5%