Ax60K Carbon Dioxide Detector
Quick Start Guide - Kiosk Option
Document ref: P0159-804-01
October 2015
Page 6 of 8
3
Installation
3.1
CO
2
Sensor
Retain the clear protective film on the fascia
until the installation is complete.
Using the
supplied paper template mark out the wall-
fixing position for the CO
2
Sensor ensuring
it is level. Drill holes in wall, install plugs/
dowels then fix the CO
2
Sensor in position.
WARNING: CARBON DIOXIDE GAS (CO
2
)
IS HEAVIER THAN AIR AND SHOULD BE
MONITORED FROM A LOW HEIGHT. YOU
SHOULD THEREFORE INSTALL THE CO
2
SENSOR AT A HEIGHT OF 12–18" (305–
457MM) ABOVE THE FLOOR LEVEL.
3.2
CO
2
Alarm
WARNING: SOME KIOSKS AND FOOD
COURT RESTAURANTS MAY BE EXPOSED
TO HIGH-VOLUME BACKGROUND NOISE.
INSTALL THE CO
2
ALARM SO THAT IT IS
AUDIBLE & VISIBLE FROM ALL ACCESS
AND EGRESS POINTS AND BUSY AREAS.
Retain the clear protective film on the fascia
until the installation is complete.
Using the
supplied paper template mark out the wall-
fixing position for the CO
2
Alarm ensuring it
is level. Drill holes in wall, install plugs/
dowels then fix the CO
2
Alarm in position.
3.3
Cables
Route the pre-wired cables from the CO
2
Sensor and CO
2
Alarm securely along the
wall. Fit the cable coupler then connect the
cables together. Then route the pre-wired
cable from the PSU securely along the wall.
3.4
Power supply
Fit the appropriate interchangeable plug
head for your power socket. Ensure the
power supply is off. Insert the plug into the
power socket.
Mark out the wall-fixing position for the PSU
securing strip. Drill holes in the wall and
install wall plugs/dowels. Fix the securing
strip firmly over the PSU.
3.5
Hazard warning/information labels
Install the hazard warning/information labels and ensure they are visible to employees.