background image

Ax60K Carbon Dioxide Detector 
Quick Start Guide - Kiosk Option 

Document ref: P0159-804-01 

October 2015 

Page 5 of 8 

2.2

 

Features 

CO

2

 Sensor 

CO

2

 Alarm 

 

 

 

 

 Power indicator (green LED) 

If the 

Power

 indicator flashes once per second: 

 

CO

2

 Sensor is receiving power and 

operating correctly. 

If the 

Power

 indicator is off: 

 

CO

2

 Sensor is not receiving power, 

or

 

the CO

2

 Sensor has a fault. 

If the 

Power

 indicator is continuously on: 

 

CO

2

 Sensor has a fault. 

 Power indicator (green LED) 

If the 

Power

 indicator is on (not flashing): 

 

CO

2

 Alarm is receiving power. 

NOTE: The CO

2

 Alarm receives its 

power from the CO

2

 Sensor. 

If the 

Power

 indicator is off: 

 

CO

2

 Alarm is not receiving power, 

or

 

 

CO

2

 Alarm has a fault. 

NOTE: If the CO

2

 Sensor has a fault 

the CO

2

 Alarm 

Fault

 LED will flash. 

 Fault indicator (yellow LED) 

If the 

Fault

 indicator is off: 

 

CO

2

 Sensor is functioning correctly. 

If the 

Fault

 indicator flashes once per second: 

 

CO

2

 Sensor has a fault. 

NOTE: The 

Fault

 indicator LED does 

not mean there is a fault on the 
CO

2

 Alarm, it means there is a fault 

on the CO

2

 Sensor. 

 Strobe light 

The strobe light is a very bright, visible alarm. 

NOTE: The strobe window can be 

supplied in white, blue or red. 

The strobe light has two flash patterns: 

 

1 second on, 1 second off = 1.5% CO

2

 

½ second on, ½ second off = 3% CO

2

 Sounder 

The sounder is a high-volume, audible alarm. 

If the sounder is ½ second on, ½ second off: 

 

The CO

2

 Sensor has triggered a high 

alarm (3% CO

2

). 

 Alarm indicator (red LED) 

The 

Alarm

 indicator has three flash patterns, one 

for each type of alarm: 

 

¼ second on, 1¾ seconds off = TWA 

alarm (0.5% CO

2

 average over 8 hours). 

 

1 second on, 1 second off = 1.5% CO

2.

 

 

 second on, 

 second off = 3% CO

2.

 

If the 

Alarm

 indicator is continuously on: 

 

the alarm is acknowledged; the alarm 

will clear when the CO

2

 level reduces. 

 Accept/Test button 

To use the 

Accept/Test

 button, press it firmly and 

hold it down for a couple of seconds. When you 

release the button, the buzzer will sound once.  

 Internal buzzer 

The internal buzzer sounds briefly when you 
press 

Accept/Test

, continuously for 5 seconds 

when the Ax60K powers up, once per second to 

show a fault, and in parallel with the alarms. 

 Sensor opening 

The sensor opening allows air to flow across the 
carbon dioxide detector. The sensor opening 

must be kept clean and free from obstructions. 

Summary of Contents for Ax60K

Page 1: ...mited 15 Ellerbeck Court Stokesley Business Park North Yorkshire TS9 5PT UK T 44 0 1642 711400 F 44 0 1642 713900 W www analox net E info analox net Ax60K Carbon Dioxide Detector Quick Start Guide Kio...

Page 2: ...ANCE OF 3 METRES WARNING DO NOT TEST THE CO2 ALARM WHEN IT IS CLOSE TO THE EYES IT HAS A HIGH VISIBILITY STROBE LIGHT WITH A LUMINOUS INTENSITY OF 100 CANDELA WARNING ENSURE YOU PERFORM A RISK ASSESSM...

Page 3: ...he level of carbon dioxide If the CO2 Sensor detects a level of CO2 above set limits it sends a signal to the CO2 Alarm The CO2 Sensor supplies power to the CO2 Alarm Power supply unit The power suppl...

Page 4: ...with blue RJ45 connector 1 x mains power supply unit PSU plug in type complete with interchangeable heads to suit the destination country 1 x PSU securing strip 1 x RJ45 coupler for connecting the cab...

Page 5: ...he CO2 Sensor Strobe light The strobe light is a very bright visible alarm NOTE The strobe window can be supplied in white blue or red The strobe light has two flash patterns 1 second on 1 second off...

Page 6: ...ALL ACCESS AND EGRESS POINTS AND BUSY AREAS Retain the clear protective film on the fascia until the installation is complete Using the supplied paper template mark out the wall fixing position for th...

Page 7: ...larm 0 5 average over the previous 8 hours CO2 Sensor indication Power indicator flashes once per second Alarm indicator flashes second on 1 seconds off Buzzer sounds in parallel CO2 Alarm indication...

Page 8: ...hat the CO2 Sensor has a fault Power off the CO2 Sensor unit and call a service engineer 6 3 Calibration The Ax60K CO2 sensor is factory calibrated and does not require periodic calibration adjustment...

Reviews: