background image

Evaluation Board User Guide 

UG-500

 

Rev. 0 | Page 9 of 15 

 

FAST CHARGE CURRENT 

To measure the fast change current, do the following: 

1.

 

Set the V

IN

 supply voltage to 5.0 V. 

2.

 

Set V

ISO_B

 to 3.9 V.  

3.

 

Verify that the GUI 

Battery Status

 indicator shows 

BAT_SNS > Vweak

4.

 

Set the VINx input current limit to the maximum value 
2100 mA. 

5.

 

Measure the charge current into the battery. The default 
value for the fast charge current is 750 mA. It is possible to 
change the fast charge current setting from 50 mA to 1300 mA 
using the GUI. 

6.

 

The fast charge current may be reduced because of the 
following conditions: 

 

The V

BAT_SNS

 level is close to the termination voltage 

V

TRM

 (default 4.20 V). 

 

The die temperature T

J

 exceeds the isothermal 

charging temperature T

LIM

 (typically 115 °C). 

TERMINATION VOLTAGE AND END OF CHARGE 
(EOC) CURRENT 

Measuring Termination Voltage Using SMU or Battery 
Simulator 

The 

ADP5062

 fast charge constant voltage (CV) regulation is 

optimized for batteries with series resistance in the 100 mΩ to 
250 mΩ range. When using a SMU or a battery simulator 
connected to the ISO_Bx, set the series resistance (R

S

 in Figure 5) 

within this range. 

Some battery simulators, such as the Keithley 2306, have 
programmable source resistance integrated in the instrument 
itself. For SMU units, use an external resistor to obtain accurate 
measurement results of the termination voltage. 

To measure the termination voltage, do the following: 

1.

 

Set the V

VIN

 supply voltage to 5.0 V. 

2.

 

Set the termination voltage to 4.2 V using the GUI. 

3.

 

Disable the EOC by setting the EN_EOC bit (D2) to low in 
the functional settings register, Register 0x07. 

4.

 

Disable charge complete timer register, Register 0x06, using 
the GUI (see Figure 3). 

5.

 

Sweep V

ISO_B

 up until 

Charger Status

 indicator in the GUI 

shows 

Fast Charge (CV-Mode)

6.

 

Sweep V

ISO_B

 up until charge current has dropped to 50 mA. In 

fast charge CV mode, 1 mV step up of V

ISO_B

 can reduce the 

charge current by several mA. 

7.

 

Measure termination voltage between the BAT_SNS (TP20) 
and GND_S (TP9) nodes. 

 

 

 

 

Measuring EOC Current 

To measure the EOC current, do the following: 

8.

 

Use the GUI to set the termination current to 52.5 mA. 

9.

 

Step V

ISO_B

 down 100 mV. 

10.

 

Enable the EOC by setting the EN_EOC bit (D2) to high in 
the functional settings register, Register 0x07. 

11.

 

Step V

ISO_B

 up and monitor the charge current for each step 

until the 

Charger Status

 indicator in the GUI shows 

Charge Complete

. The last charge current value before 

Charge Complete

 is the charge complete current threshold. 

Charging stops and there is no current flowing into the 
ISO_Bx node. 

Measuring Recharge Voltage 

To measure the recharge voltage, do the following: 

12.

 

Step V

ISO_B

 down and monitor the voltage until the 

Charger Status

 indicator on the GUI shows 

Fast Charge 

(CC-Mode)

 and charge current flows to the ISO_Bx node. 

Last value before the charger status change is the recharge 
voltage level. With default settings, the recharge voltage 
threshold is 3.94 V (V

ISO_B

). 

13.

 

Use the GUI to change the termination current and 
recharge voltage programming. Repeat Step 9 to Step 12 to 
evaluate different settings.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ADP5062

Page 1: ...g Devices Inc SOFTWARE REQUIREMENTS Analog Devices ADP5062 SDP evaluation software GENERAL DESCRIPTION The ADP5062 charger evaluation system is composed of an evaluation board an USB A to USB micro B...

Page 2: ...the Software Graphical User Interface GUI 4 Operating the Board with the GUI 4 Basic Charging Parameter Settings 4 Setting Interrupts 5 Setting Timers 5 Direct Register Read and Write 6 Evaluation Boa...

Page 3: ...uation software the drivers for the USB SDP CABLEZ must be installed The software and the instructions can be obtained from www analog com usb sdp cablez After proper installation of the USB SDP CABLE...

Page 4: ...UI SDP Once this step is done the software is ready to use VIN must be above 2 5 V in order for the I2 C communication of the ADP5062 to start working The VIN voltage level is monitored and the indica...

Page 5: ...automatically read after every 0 3 second timeout from the last user action involving the GUI When a certain interrupt is enabled and there is a status change in the corresponding function during char...

Page 6: ...ontents of each register in the GUI A single register read or write can be done using the controls on the right side of the Register R W tab of the GUI Type the I2 C sub address in the Sub Address for...

Page 7: ...variable power resistor or electronic load for the ISO_S_x pins The SMU at the ISO_B node must have a 100 m to 250 m resistor RS in series with its positive lead The resistor emulates the equivalent s...

Page 8: ...e the higher end of the input current limit programming range TRICKLE CHARGE CURRENT Trickle charge can only be activated during a battery charging startup sequence if the voltage level at the ISO_Bx...

Page 9: ...ge to 5 0 V 2 Set the termination voltage to 4 2 V using the GUI 3 Disable the EOC by setting the EN_EOC bit D2 to low in the functional settings register Register 0x07 4 Disable charge complete timer...

Page 10: ...et VISO_B to 3 9 V 3 Set the charge current setting to 750 mA using the GUI 4 Set VIN input current limit to 1500 mA 5 Enable charging EN_CHG high 6 Measure current to ISO_Bx value should be 750 mA 7...

Page 11: ...uF TP11 1 SN3 JP3 HeaderLarge10x2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 R16 0R TP20 1 C2 1u R5 N A C6 100n TP13 1 R1 56k TP9 1 R11 0R ISO_B_S ISO_B_F SYS_EN BAT_SNS SDA ISO_S_S SCL AGND A...

Page 12: ...tor headers 3 pins 1 pin Sullins Electronics PEC36SAAN 6 J5 J6 J7 J8 J9 J10 Connector headers 2 pins 1 pin Sullins Electronics PEC36SAAN 1 R1 Resistor 56 k 1 0805 SMD Vishay or equivalent CRCW080556K0...

Page 13: ...Evaluation Board User Guide UG 500 Rev 0 Page 13 of 15 NOTES...

Page 14: ...UG 500 Evaluation Board User Guide Rev 0 Page 14 of 15 NOTES...

Page 15: ...party for any reason Upon discontinuation of use of the Evaluation Board or termination of this Agreement Customer agrees to promptly return the Evaluation Board to ADI ADDITIONAL RESTRICTIONS Custome...

Reviews: