Rev. 0 | Page 8 of 15 

 

Figure 6. Board Setup for VINx Quiescent Current Measurement 

VINx Current Limit 

The VINx current limit of the 

ADP5062

 can be evaluated in 

charging mode. Note that the maximum programming for the 
charge current into the battery (ISO_Bx) is 1300 mA. For 
measuring the input current limit across the full programming 
range from 100 mA to 2100 mA, additional system load has to 
be connected to the ISO_Sx pins. 

To measure the VINx current limit, do the following: 

1.

 

Set the V

VIN

 supply voltage to 5.0 V. 

2.

 

Set the V

ISO_B

 voltage to 3.6 V on SMU B 

3.

 

Enable charging by setting Register 0x07, bit D0 
(EN_CHG), high 

4.

 

Confirm the ADP5062 charging mode: 

 

The 

Battery Status

 indicator on the GUI must show 

BAT_SNS > Vweak

 (see Figure 2). 

 

The 

ADP5062

 must start charging 80 mA to 90 mA 

current into the battery. 

5.

 

Measure the current on VINx supply. 

6.

 

Use the GUI to change the input current limit programming 
and repeat the measurement. 

A 1300 mA charge current into the battery may not be large 
enough to drive the input current up to the limit when the 
current limit programming values of 1200 mA or higher are used. 
Connect an additional load on the ISO_Sx node to evaluate the 
higher end of the input current limit programming range. 

TRICKLE CHARGE CURRENT 

Trickle charge can only be activated during a battery charging 
startup sequence, if the voltage level at the ISO_Bx pins is lower 
than the V

TRK_DEAD

 threshold (typically 2.5 V). When V

VIN

 is 5.0 

V, initiate a charge startup sequence by setting an I

2

C write of 

Register 0x07, Bit D0 (EN_CHG), high. To measure the trickle 
charge current level, do the following:  

1.

 

Set the V

ISO_B

 voltage (SMU or battery simulator) to 2 V. 

2.

 

Set the V

IN

 supply voltage to 5.0 V. 

3.

 

Check that the GUI 

Charger Status 

indicator shows 

Trickle Charge

4.

 

Check that the GUI 

Battery Status

 indicator shows 

BAT_SNS < Vtrk

5.

 

Check the battery short detection by doing the following: 

 

Wait for a 30 second timeout to expire 

 

Check that the GUI shows that the I

2

C fault register 

(Register 0x0D, Bit D3) BAT_SHR flag is set. 

 

Use the GUI to change the battery short timeout 
setting from 1 second to 180 second.  

6.

 

Measure the trickle charge current level to the battery. The 
default value for I

TRK_DEAD

 is 20 mA. It is possible to change 

the trickle charge current setting from 5 mA to 80 mA 
using the GUI. 

7.

 

Adjust the V

ISO_B

 voltage up until the 

Battery Status

 indicator 

shows 

Vtrk < BAT_SNS < Vweak

8.

 

The 

Charger Status

 indicator on the GUI should show 

Fast 

Charge (CC-Mode)

. The charge current is now programmed 

I

CHG

 + I

TRK_DEAD

, if it is not limited by the input current limit. 

 

 

 

 

Summary of Contents for ADP5062

Page 1: ...g Devices Inc SOFTWARE REQUIREMENTS Analog Devices ADP5062 SDP evaluation software GENERAL DESCRIPTION The ADP5062 charger evaluation system is composed of an evaluation board an USB A to USB micro B...

Page 2: ...the Software Graphical User Interface GUI 4 Operating the Board with the GUI 4 Basic Charging Parameter Settings 4 Setting Interrupts 5 Setting Timers 5 Direct Register Read and Write 6 Evaluation Boa...

Page 3: ...uation software the drivers for the USB SDP CABLEZ must be installed The software and the instructions can be obtained from www analog com usb sdp cablez After proper installation of the USB SDP CABLE...

Page 4: ...UI SDP Once this step is done the software is ready to use VIN must be above 2 5 V in order for the I2 C communication of the ADP5062 to start working The VIN voltage level is monitored and the indica...

Page 5: ...automatically read after every 0 3 second timeout from the last user action involving the GUI When a certain interrupt is enabled and there is a status change in the corresponding function during char...

Page 6: ...ontents of each register in the GUI A single register read or write can be done using the controls on the right side of the Register R W tab of the GUI Type the I2 C sub address in the Sub Address for...

Page 7: ...variable power resistor or electronic load for the ISO_S_x pins The SMU at the ISO_B node must have a 100 m to 250 m resistor RS in series with its positive lead The resistor emulates the equivalent s...

Page 8: ...e the higher end of the input current limit programming range TRICKLE CHARGE CURRENT Trickle charge can only be activated during a battery charging startup sequence if the voltage level at the ISO_Bx...

Page 9: ...ge to 5 0 V 2 Set the termination voltage to 4 2 V using the GUI 3 Disable the EOC by setting the EN_EOC bit D2 to low in the functional settings register Register 0x07 4 Disable charge complete timer...

Page 10: ...et VISO_B to 3 9 V 3 Set the charge current setting to 750 mA using the GUI 4 Set VIN input current limit to 1500 mA 5 Enable charging EN_CHG high 6 Measure current to ISO_Bx value should be 750 mA 7...

Page 11: ...uF TP11 1 SN3 JP3 HeaderLarge10x2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 R16 0R TP20 1 C2 1u R5 N A C6 100n TP13 1 R1 56k TP9 1 R11 0R ISO_B_S ISO_B_F SYS_EN BAT_SNS SDA ISO_S_S SCL AGND A...

Page 12: ...tor headers 3 pins 1 pin Sullins Electronics PEC36SAAN 6 J5 J6 J7 J8 J9 J10 Connector headers 2 pins 1 pin Sullins Electronics PEC36SAAN 1 R1 Resistor 56 k 1 0805 SMD Vishay or equivalent CRCW080556K0...

Page 13: ...Evaluation Board User Guide UG 500 Rev 0 Page 13 of 15 NOTES...

Page 14: ...UG 500 Evaluation Board User Guide Rev 0 Page 14 of 15 NOTES...

Page 15: ...party for any reason Upon discontinuation of use of the Evaluation Board or termination of this Agreement Customer agrees to promptly return the Evaluation Board to ADI ADDITIONAL RESTRICTIONS Custome...

Reviews: