TROUBLESHOOTING
Debugging the Evaluation Board Using On-Board LEDs
There are six LEDs on the AD9166-FMC-EBZ evaluation board:
DS1, DS2, DS3, DS4, DS5, and DS8.
12 V power LED: DS2 = on indicates that 12 V was applied
to the evaluation board.
power sequencer LEDs: DS8 = on and DS1 = off
indicate that the
supplies have sequenced correctly
and the monitored supplies are within the specified voltage
range, according to the limits programmed in the
. DS1 = on indicates a power sequencing fault. For
debugging, the response of the
to a fault
condition can be overridden by shorting the 2-pin header,
P2. Shorting P2 signals to the
to maintain power
despite a sequencing fault, which in turn
may damage the
fault LED: DS4 = on indicates an issue with the
. When either PLL1 or PLL2 is used, an on state
indicates that one of the PLLs did not lock. When PLL1
and PLL2 are not used, an on state indicates an issue with
the output dividers. This LED is connected to a general-
purpose input/output (GPIO) pin, and its function can be
programmed by writing to the appropriate
SPI
register.
fault LED: DS5 = on indicates the
PLL
locked correctly. This LED turns on only if the
used to generate a clock. This LED stays off by default. This
LED is connected to the MUXOUT pin of the
and its function can be programmed by writing to the
appropriate
SPI register.
interrupt request (IRQ) LED: DS3 is connected to
the IRQ pin of the
. DS3 = on may indicate an
unreliable JESD204B link, or another fault as reported by
the
. The specific error can be read from the
data sheet for details. In
a tested platform such as the AD9166-FMC-EBZ evaluation
board, the majority of JESD204B link issues are due to
improperly configured external clocking. Make sure all
clocks are properly configured and are set to the correct
frequencies.
When the AD9166-FMC-EBZ evaluation board is properly
configured, the LEDs illuminate as follows:
DS2 = on
DS8 = on and DS1 = off
DS4 = off
DS5 = on (if the
is used)
DS3 = off
DPGDownloader Does Not Recognize the Evaluation
Board
The AD9166-FMC-EBZ evaluation board can be run with or
without an
, as long as it is connected across the
FMC connector to a carrier board that supports the VITA 57.x
standard.
, connect the evaluation board to
its FMC connector. With a USB cable connecting the
to a PC, open the
DPGDownloader
software. When the
DPGDownloader
software recognizes the
, it
attempts to read the evaluation board ID of the AD9166-FMC-
EBZ through the FMC connector and across an I
2
C bus. With a
board recognized, the
DPGDownloader
uploads the image
. The image must
correspond to the evaluation board that is connected to the
. With the image loaded, the ADS7 then applies
power to the AD9166-FMC-EBZ evaluation board.
If the
DPGDownloader
software does not recognize the evalua-
tion board, it does not load an FPGA image and does not apply
power to the evaluation board. If no FPGA image is loaded and
no power is applied to the evaluation board, confirm all hardware
is properly connected. Close the
DPGDownloader
software,
, unplug the USB cable, and
gently unplug the evaluation board from the FMC connector.
Inspect the FMC connector for bent pins or other damage.
Then reconnect the hardware and reopen
DPGDownloader
.
If
DPGDownloader
still does not recognize the AD9166-FMC-
EBZ evaluation board, make sure that it is the latest version availa-
ble at
wiki.analog.com/resources/eval/dpg/dacsoftwaresuite
It is possible that the firmware on the
is outdated.
The firmware can be updated from
DPGDownloader
if
necessary. Refer to the
section for more details.
DPGDownloader Does Not Recognize an
To confirm that the
DPGDownloader
software recognizes a
particular
board, connect the board to a PC using a
USB cable. If the evaluation board is not connected to the FMC
port of the
, the
DPGDownloader
software
automatically loads a generic FPGA image onto the
. However, if the AD9166-FMC-EBZ evaluation board is
connected to the FMC port, the DPG Downloader attempts to
recognize the evaluation board and loads an FPGA image onto the
that is compatible with the AD9166-FMC-EBZ
evaluation board.
JESD204B Link Does Not Come Up
The start-up sequences for the JESD204B link, as referenced in
this user guide, are tested on the AD9166-FMC-EBZ evaluation
board and are known to work. If the JESD204B link does not
synchronize correctly (does not come up), an issue with the
clocking configuration or settings is likely.