background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

6/08

©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time. 

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

 

REV: B

    93-1330-1501-04

Video Pin Connectors 

FIG. 2 provides the pin layout for the RBGHV HD-15 connectors: 

The pin configuration for the HD-15 (video) connector are as follows: 

Audio 3.5mm 3-Pole Connectors

The pin configuration for the 3.5mm 3-pole audio connectors are as follows: 

Operation 

Manual Operation

1.

Connect Mains to unit. BLANK/MUTE LED will light.

2.

Press button 1 to 6 to select required input source. The corresponding 
LED will light.

3.

To Blank or Mute the outputs press the BLANK/MUTE button.

Auto-Switch Mode

1.

Set the HEX switch on the rear of the unit to F.

2.

Connect Mains to unit. BLANK/MUTE LED will light.

• The unit will scan the Vertical sync inputs from 1 to 6 and if any RGBHV 

input sources are active the unit will switch to the last detected input. The 
corresponding LED will light.

• Input sources are changed either from the front panel or by connecting a 

RGBHV source to any of the inputs. The unit will switch and hold to the 
last detected input or button selected.

3.

To switch back to an active input either select the input from the front 
panel or temporarily disconnect the input from the PC and then recon-
nect. 
Alternatively, if using a Laptop, toggle through the Video modes until the 
Video Output is turned off then on again. (usually by holding the FN key 
with a Function key.)

Note

: For the auto-switch function to operate the Input sources must be 

RGBHV as the unit searches for any newly introduced Vertical sync.

Audio Switching

The audio inputs will switch to the corresponding RGBHV selected input.

RS232 Control

Options are available for Front Panel operation and RS232 from AMX control 
systems. Alternatively a Computer with a RS232 output can be used.
1.

Connect the unit as previously described in Manual Operation.

2.

Connect also the RS232 connection RX TX and GND.

In such cases the programming protocol is as follows:

All units can be individually addressed 0 - 15 by setting the HEX switch on rear 
of unit. 
RS232 connection on unit is by 3-Pin Socket:

Several units may be linked together by connecting the signal lines in parallel.
Units can then be globally or individually addressed.

Input Switch Commands 

Each time the unit switches to a new input the following return code is 
transmitted from the TX Port.

 

Note

: Byte numbers are shown in Hexadecimal.

Full Interrogate

This command is an input query, and it returns the current input:
Sending this command: 

The unit will return the following information: 

Identity Command

This command is a model query, and it returns the model number. 
Sending this command: 

The unit will return the following information: 

For example, if Byte 2 of the response is 

0x01

, then the unit is a 1501 model.

FIG. 2  

RGBHV HD-15 connector

1 - RED

9 - n/c

2 - GREEN

10 - SYNC GROUND

3 - BLUE

11 - n/c

4 - n/c

12 - n/c

5 - n/c

13 - H SYNC

6 - RED GROUND

14 - V SYNC

7 - GREEN GROUND

15 - n/c

8 - BLUE GROUND

• Tip

L

• Ring

R

• Sleeve

Ground

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

RS232 DATA

• Baud Rate: 9600

• Parity:

none

• Data:

8 Bits

• STOP:

1 Bit

PC Serial Port D9

• Pin 2:

to Switcher TX

• Pin 3:

to Switcher RX

• Pin 5:

to Switcher GND

Byte 1 (Header)

Byte 2 (Address)

Byte 3 (Input) 

FC

00 to 0F

01 to 06 (00 for Blank/Mute)

Byte 1

Byte 2

Byte 3

C8

Address No.

Current Input No.

Byte 1 (Header) Byte 2 (Address) Byte 3 (Input) 

FC

00 to 0F

80

Byte 1

Byte 2

Byte 3 

Byte 4 (null) 

Byte 5 (null)

C8

00 to 0F

0 - 06

FF

FF

Byte 1

Byte 2

Byte 3 

Byte 4

F2

09

EA

80

Byte 1

Byte 2

6E

01 = 1501

Reviews: