Controlling the System
31
Precis DSP Instruction Manual
Executing a Test Switch with BCS
The following test switch routes Input 2 to Output 1 (the level does not need to be specified since the
Precis DSP only switches audio).
To execute a test switch using BCS commands:
1.
Enter the following BCS command line:
CI2O1T
When the “
T
” appears, the system has successfully executed the command. If any other characters
appear, the command was not successful. Verify that the source signal is audible at the destination.
Important:
When entering values for BCS gain commands, do not add any leading zeros (e.g., to
set the volume to -9 dB, enter
CO3VA-90T
, do not enter
CO3VA-090T
).
Troubleshooting
If the test switch did not execute correctly:
Check the power indicator on the front of the enclosure.
If it is not illuminated, check the power cords.
Verify the status of the test switch.
If using BCS commands, enter “
SO1T
”. If “
SO1T(2)
” appears, the test switch is routed.