Novara ControlPads
8
Novara ControlPads & KeyPads
Relay 1 / Relay 2 Connectors
The "Relay 1" and "Relay 2" Output ports each act as a switch to GND and are rated at 100 mA @ 12 VDC. These
Output ports are used to control external devices (i.e. the PC1 Power Controller or AMX UPC-20+ Universal Power/
Motor Controller - not included).
These Output ports do not function like "Relay" ports on other AMX equipment:
The Relay 1 and Relay 2 output ports are current sinks, not voltage drivers, they switch the ports to GND.
The "12V" connector is 12 VDC (not Ground).
These Output ports use 5V logic, but can handle up to 12V on the input without harm - at higher voltages you
run a higher risk of surge damage.
FIG. 8 illustrates connecting the RELAY 1 (Output) Connectors to a PC1 Power Controller, in momentary/latching
mode.
The Relay ports are for external relay control only.
FIG. 8
Relay 1 / Relay 2 Connectors - Connected to PC1 Power Controller in momentary/latching mode
SHARED 12V
Control Wiring connector
on PC1 (rear panel)
PC1 Pinouts