Programming the Mio R-4
49
Mio Modero R-4
"^" Button Commands
These Button Commands are used in the NetLinx protocol and are case insensitive.
All commands that begin with "
^
" have the capability of assigning a variable text address range and
button state range.
A device must first be defined in the NetLinx programming language with values
for the Device: Port: System
(in all programming examples -
Remote
is used in place of these values).
Variable text ranges
allow you to target one or more variable text channels in a single
command.
Button State ranges
allow you to target one or more states of a variable text button with a
single command.
The
"."
Character is used for the 'through' notation, also the "
&
" character is used for the
'And' notation.
"^" Button Commands
^ANI
Run a button
animation
(in 1/10 second)
Run a button animation (in 1/10 second).
Syntax:
"'^ANI-<vt addr range>,<start state>,<end state>,<time>'"
Variable:
• variable text address range = 1 - 4000.
• start state = Beginning of button state (0= current state).
• end state = End of button state.
• time = In 1/10 second intervals.
Example:
SEND_COMMAND Panel,"'^ANI-500,1,25,100'"
Runs a button animation at text range 500 from state 1 to state 25 for 10 second.
^APF
Add page flip
action to a button
if it does not
already exist
Add page flip action to a button if it does not already exist.
Syntax:
"'^APF-<vt addr range>,<page flip action>,<page name>'"
Variable:
• variable text address range = 1 - 4000.
• page flip action =
Stan
[dardPage] - Flip to standard page
Prev
[iousPage] - Flip to previous page
Show
[Popup] - Show Popup page
Hide
[Popup] - Hide Popup page
Togg
[lePopup] - Toggle popup state
ClearG
[roup] - Clear popup page group from all pages
ClearP
[age] - Clear all popup pages from a page with the
specified page name
ClearA
[ll] - Clear all popup pages from all pages
• page name = 1 - 50 ASCII characters.
Example:
SEND COMMAND Device,"'^APF-400,Stan,Main Page'"
Assigns a button to a standard page flip with page name 'Main Page'.