5. INSTALLATION AND WIRING
5.1 Installation
CAUTION: Before installation, please ensure the Matrix is disconnected from the
power source.
DUX-8C occupies 1U space and can be placed on a solid and stable surface or installed
on a standard equipment rack.
To install the Matrix on an equipment rack:
1. Discharge any static electricity from your body by touching a grounded metal
object.
2. Position and install the mounting brackets using the mounting screws provided.
Brackets attach at the side
toward the front of the Matrix
3. Install the Matrix in the mounting rack by using the mounting screws to affix the
Matrix to the rack.
4. Connect any applicable wires to the device. (For detailed information of wiring,
please refer to 5.3 Wiring.)
CAUTION: DO NOT place other units directly on top of the Matrix when it is rack
mounted, as this will place excessive strain on the mounting brackets.
CAUTION: When adopting rackmouting, distribute the units evenly. Otherwise,
hazardous conditions may be caused by an uneven weight distribution.
CAUTION: Reliable earthing of rack-mounted equipment should be maintained.
5.2 Ventilation
ALWAYS ensure the Matrix is adequately ventilated. Do not block any ventilation
openings. Sufficient airflow must be achieved (by convention or force-air cooling) to
satisfy the ventilation requirements of all the equipment installed within the rack.
NOTE: The maximum operating temperature of the Matrix is 45°C (113°F).