Appendix A – Product Specific BCS Commands
29
Instruction Manual – BCS Basic Control Structure Protocol
Epica DG, Epica DGX 16, Epica DGX 32, and Epica DGX 144
The Epica DG, Epica DGX 16, Epica DGX 32, and Epica DGX 144 support the following items:
General Commands
Executing and disconnecting switches (see page 6 and page 7)
Verifying signal status (see page 8)
Executing local presets – predefined in XNConnect (see page 10); the Epica DG and
Epica DGX 144 each support 335 local presets, and the Epica DGX 16 and Epica DGX 32
each support 64 local presets
Defining and executing global presets (see page 11); these products support 64 global presets
Specific Commands
The Epica DG, Epica DGX 16, Epica DGX 32, and Epica DGX 144 support fragmented status reporting
(see page 9) and error code reporting (see page 41).
Diagnostic Commands
The Epica DG, Epica DGX 16, Epica DGX 32, and Epica DGX 144 display system information in the
splash screen for diagnostic purposes. The information indicates the current status and well-being for
some of the system components. For information on system diagnostics that includes the commands and
applies to all systems that support diagnostic commands, see page 45.
Component Settings
The Epica DG, Epica DGX 16, Epica DGX 32, and Epica DGX 144 all support the eight component
identity number settings (
i0
through
i7
) in the following table.
Tip:
The information in the above table is displayed when you enter
~scr!
or
~scrv0i0!
Auxiliary Commands
Component
Identity Number
All Components
i0
Enclosure
i1
Storage Blocks
i2
Communication Interfaces
i3
Hardware / Boards
i4
VM Configuration
i5
Power System
i6
System Sensors
i7
Auxiliary Commands Supported by
Epica DG, Epica DGX 16, Epica DGX 32, and Epica DGX 144
To cause a warm reboot
~app!