![background image](http://html.mh-extra.com/html/amx/bcs/bcs_instruction-manual_2938897018.webp)
Adjusting and Verifying Audio
15
Instruction Manual – BCS Basic Control Structure Protocol
Volume Mute and Unmute Examples
Verifying Volume Status
Note:
Multiple levels or outputs cannot be entered in volume status commands.
The volume setting of the output will display in parentheses (
), even if the output is not receiving a
signal. The decibel amount in the result is specified as an integer number representing the actual decibel
value multiplied by 10. For example, if the result is -480, the decibel level is at -48 or if the result is 65,
the decibel level is at 6.5. If the status result is
(
M
)
, the volume is muted.
To verify the volume status of a specific output:
1.
Enter the Verify Volume Status command below. Replace the “
#
”s with the level and output
number.
SL#O#VT
Volume Status Examples
BCS Command
Action
CL0O24VMT
Mutes Output 24 on Level 0
CL0O2 4VMT
Mutes Outputs 2 and 4 on Level 0
CL0O2:8VMT
Mutes Outputs 2, 3, 4, 5, 6, 7, and 8 on Level 0
CL0O5VUT
Unmutes Output 5 on Level 0
CL0O11
15VUT
Unmutes Outputs 11 and 15 on Level 0
BCS Command
Status Result
Explanation of Result
SL0O37VT
SL0O37VT( 100 )
Volume for Output 37 on Level 0 is at 10 dB
SL0O8VT
SL0O8VT( 5 )
Volume for Output 8 on Level 0 is at 0.5 dB
SL0O22VT
SL0O22VT( -700 )
Volume for Output 22 on Level 0 is at -70 dB
SL0O41VT
SL0O41VT( M )
Verifies the volume is muted for Output 41 on Level 0