Installing a CP-20A Remote
35
CP-20A Instruction Manual
Linking Multiple Panels
CP-20A Remote Panels can be linked together in a daisy chain to create multiple control points for a
single system.
Note
:
If any of the linked CP-20A remote panels were not part of the original system, the current
configuration file must be uploaded to the remote; for instructions see page 29
.
Cable Requirements
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield, such as Alpha 2412C
(customer supplied)
Total distance of the cable runs cannot exceed 1,000 ft. (304.8 m)
Power Requirements
+
9 volt DC with at least 500 mA
Important
:
Always use a UL approved power source. Be sure to check the power source
documentation for information specific to that power source.
To link CP-20A Remote Panels to each other:
1.
Connect the first panel to the AMX AutoPatch Router using one of the Comm Links (see page 32
for instructions).
2.
Attach an XNNet link cable to the other Comm Link on the first panel (follow the same procedure
used when connecting to the AMX AutoPatch Router).
3.
Attach the other end of the XNNet link cable to a Comm Link on the next panel.
4.
Repeat Steps 2 and 3 for any additional panels to be linked.
5.
Wire the power connectors on each of the CP-20A Remote Panels.
6.
Place the panels in a rack(s) or in other permanent installation locations.
7.
Apply power from each of the power sources.
FIG. 9
Comm Links connected in a daisy chain
XNNet Link Cable to router
XNNet Link Cable