Programming
28
Anterus RFID Solution
DEFINE_EVENT
DATA_EVENT[vdvAnterus]
{
ONLINE:
{
SEND_COMMAND vdvAnterus,'PROPERTY-Identifiers,97;98;99'
SEND_COMMAND vdvAnterus,'REINIT'
}
}
Port Mapping
This module uses a single virtual device:
Channels
The channels supported by the COMM module are listed below. These channels are associated with the virtual
device(s) and are independent of the channels associated with the touch panel device.
NetLinx Send Commands
There are two sets of NetLinx Send Commands supported by the COMM module, one set of Control
commands and one set of Feedback commands.
Refer to the documentation supplied with the Anterus Duet Module for a full listing and description of
supported NetLinx commands, as well as Installer Tips, Naming Conventions, Programming Notes, etc.
AxLink Programming Overview
The Anterus solution will also work without the Duet module, and all web configuration may be done with
Send Commands, Channels and Levels.
Send Commands
The Anterus solution supports the AxLink Send Commands commands listed below. Note command messages
either do not have a response, or are responded to with a COMMAND - not a string.
Port Mapping
Virtual Device
Channels
Control
Feedback
41001:1:0 – Main
All
All
All
Virtual Device Channel Events
Channel
Description
251
ON: Device communicating (feedback only)
OFF: Device not communicating (feedback only)
252
ON: Data initialized (feedback only)
OFF: Data not initialized (feedback only)
Send Commands
RSSI Threshold
The RSSI Upper and Lower Thresholds will be sent from the Master to the
ANT-RDR in a level update message as described in the
AXLink
Levels
section on page 31.
• The level value is equivalent to the RSSI value with range 0 to 255.
RSSI Sensitivity Range
The RSSI Upper and Lower Thresholds will be sent from the Master to the
ANT-RDR in a level update message as described in the
AXLink
Levels
section on page 31.
• The level value is equivalent to the RSSI value with range 0 to 255.