background image

8

7. WIRING

LINE

LINE

MOTOR

MOTOR

BLACK

WHITE/STRIPE

BLUE

WHITE

TAB

TAB

SCREW

1. Shut off the circuit breaker for the well system. Loosen 

the top screw housing cover. Flip the cover forward and 
remove to expose the control wires.

 

 

Electrocution hazard. For your safety, 

the  information  in  this  manual  must  be  followed  to 
minimize  the  risk  of  electric  shock,  property  damage 
or personal injury. Properly ground to conform with all 
governing codes and ordinances. 

2. The 12 gauge wire leads are pre-stripped and ready to 

accept standard wire nuts. Each wire is color coded to 
correspond with the diagram below. Conduit knockouts 
are provided at the back of the control mounting plate. 
Attach  the  ground  wire  to  the  green  ground  screw 
provided.  Use  water  tight  conduit,  connections,  and 
wire nuts for an outside application.

3.  Wiring  is  similar  to  a  traditional  mechanical  pressure 

switch.  Two  leads  are  connected  to  line  supply,  while 
the  other  supply  the  pump  motor  or  starter.  Wire  the 
control  to  the  line  supply  and  pump  motor  or  pump 
starter  as  required  by  the  manufacturer's  instructions. 
It  is  recommended  that  service  switch  be  installed  in 
addition  to  the  circuit  breaker.  The  disconnect  for  the 
controller  must  break  all  incoming  power  lines.  This 
should  interrupt  line  voltage  and  be  installed  near  the 
Well-X1

 and labeled appropriately. 

4. After completing the wiring, reattach the front cover by 

inserting  the  plastic  tabs  and  snapping  the  cover  into 
place. Tighten the top screw and ensure no loose wires 
protrude from the housing.

Summary of Contents for WELL-X-TROL

Page 1: ...LT IN SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGUL...

Page 2: ...URE TO FOLLOW INSTRUCTION MANUAL CAN CAUSE A RUPTURE OR EXPLOSION POSSIBLY CAUSING SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE DONOTADJUSTTHEPRE CHARGEPRESSURE IF THERE HAS BEEN A REDUCTION OF THE...

Page 3: ...ontrol and tank fittings are factory installed After removing from the carton inspect the Well X1 for damage and ensure all components are present CONDUIT HOLES PUMP POWER WIRES AIR CHARGING VALVE REL...

Page 4: ...WX1 202 5 WX1 202 WX1 202 WX1 202 WX1 203 7 WX1 203 WX1 203 WX1 203 WX1 203 10 WX1 203 WX1 250 WX1 250 WX1 251 12 WX1 250 WX1 250 WX1 251 WX1 251 15 WX1 251 WX1 251 WX1 302 WX1 302 18 WX1 251 WX1 302...

Page 5: ...ing and or property damage install with a drip pan connected to an adequate working drain kept clear at all times ORIENTATION Ensure the installation meets all applicable local codes and is installed...

Page 6: ...s can cause a rupture or explosion possibly causing serious or fatal injury flooding and or property damage 2 Install the supply piping from the well pump If required install a spring loaded check val...

Page 7: ...system or into the water treatment equipment if present 6 Install a blow down tube from the relief valve to a drain or to within 6 of the floor as required by local codes A drip pan connected to an a...

Page 8: ...nting plate Attach the ground wire to the green ground screw provided Use water tight conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical press...

Page 9: ...y will read 88 to test the display illumination then a number identifying the control type i e 07 This number is for factory use and may vary by model and manufacture date 4 After a slight pause the p...

Page 10: ...ty 6 Slowly open the service valve to allow the system to pressurize The pressure may drop slightly during this process After the valve is fully open open the fixture closest to the Well X1 to begin d...

Page 11: ...ceptance is not exceeded Adjust the precharge as shown on page 12 CAUTION Exceeding Maximum Acceptance will reduce tank life and cause irreparable damage CUT OUT PRESSURE CUT IN PRESSURE 20 25 30 35 4...

Page 12: ...damage or water interruption DANGER Explosion Hazard If the Well X1 has been in service and a change to a higher pre charge is necessary due to a required change in the setting failure to follow instr...

Page 13: ...e runtime indicate an incorrect precharge undersized Well X1 or waterlogged tank Pump continues to run E2 Low Suction Pump operation below 10 psi indicates a low well level well piping leak insufficie...

Page 14: ...Check pump wiring Display will not illuminate 1 Circuit breaker or switch off 2 Faulty or loose wiring 3 Failed control 1 Check breaker and service switch 2 Check line supply wiring 3 Replace Pump wi...

Page 15: ...17 140R517 140R517 140R517 140R517 Pressure sensor tubing 6 9403R197 9403R197 9403R197 9403R197 9403R197 Pressure sensor fitting elbow 7 9401R100 9401R100 9401R100 9401R100 9401R100 Pressure sensor fi...

Page 16: ...NTIES INCLUDINGTHEIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULAR PURPOSE ARE SPECIFICALLY DISCLAIMED Some states do not allow limitations on how long an implied Warranty lasts so the above...