background image

11

1. To enter the programming mode, press and hold the 

MODE  button  until  LO  appears.  This  is  the  cut-in 
setting. Factory default will be 40 psi.

2. Use the 

and 

arrows  to  raise  or  lower  the  cut-

in setting.  Adjustment can be made within 10 psig or 
as wide as 55 psig of the cut-out setting to 60 psig. If 
this range is exceeded, the display will cease to change 
even though the button is being pressed.

  Minimum setting is 10 psig.

PRESSURE ADJUSTMENT

The Well-X1

 utilizes a simple cut-in/cut-out adjustment. Before setting the desired operating range, refer to the chart 

below to ensure the Well-X1's Maximum Acceptance is not exceeded. Adjust the precharge as shown on page 12.

CAUTION! Exceeding Maximum Acceptance will reduce tank life and cause irreparable damage.

CUT-OUT PRESSURE

CUT

-IN PRESSURE

20 25 30 35 40 45 50 55 60 65 70 75

80

10 .28 .38 .45 .50 .55 .59 .62 .65 .67 .69
15

.25 .34 .40 .46 .50 .54 .57 .60 .63 .65

20

.22 .30 .37 .42 .46 .50 .64 .57 .59 .61

25

 

.20 .27 .34 .39 .43 .47 .50 .53 .56 .58

30

.18 .25 .31 .36 .40 .44 .47 .50 .53

35

.17 .23 .29 .34 .38 .41 .45 .48

40

.16 .22 .27 .31 .35 .39 .42

45

.14 .20 .25 .30 .33 .37

50

.13 .19 .24 .28 .32

55

.13 .18 .22 .26

60

.12 .17 .21

65

.12 .16

70

.11

Step 1: Find the Maximum Acceptance for the installed 
Well-X1

 model.

Step 2: Ensure the desired operating range does not 
exceed that model's Maximum Acceptance.

MODEL

MAXIMUM 

ACCEPTANCE

WX1-202

.57

WX1-203

.35

WX1-250

.77

WX1-251

.55

WX1-302

.54

PRESS AND 

HOLD TO 

UNLOCK AND 

SET CUT-IN

t

t

Summary of Contents for WELL-X-TROL

Page 1: ...LT IN SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGUL...

Page 2: ...URE TO FOLLOW INSTRUCTION MANUAL CAN CAUSE A RUPTURE OR EXPLOSION POSSIBLY CAUSING SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE DONOTADJUSTTHEPRE CHARGEPRESSURE IF THERE HAS BEEN A REDUCTION OF THE...

Page 3: ...ontrol and tank fittings are factory installed After removing from the carton inspect the Well X1 for damage and ensure all components are present CONDUIT HOLES PUMP POWER WIRES AIR CHARGING VALVE REL...

Page 4: ...WX1 202 5 WX1 202 WX1 202 WX1 202 WX1 203 7 WX1 203 WX1 203 WX1 203 WX1 203 10 WX1 203 WX1 250 WX1 250 WX1 251 12 WX1 250 WX1 250 WX1 251 WX1 251 15 WX1 251 WX1 251 WX1 302 WX1 302 18 WX1 251 WX1 302...

Page 5: ...ing and or property damage install with a drip pan connected to an adequate working drain kept clear at all times ORIENTATION Ensure the installation meets all applicable local codes and is installed...

Page 6: ...s can cause a rupture or explosion possibly causing serious or fatal injury flooding and or property damage 2 Install the supply piping from the well pump If required install a spring loaded check val...

Page 7: ...system or into the water treatment equipment if present 6 Install a blow down tube from the relief valve to a drain or to within 6 of the floor as required by local codes A drip pan connected to an a...

Page 8: ...nting plate Attach the ground wire to the green ground screw provided Use water tight conduit connections and wire nuts for an outside application 3 Wiring is similar to a traditional mechanical press...

Page 9: ...y will read 88 to test the display illumination then a number identifying the control type i e 07 This number is for factory use and may vary by model and manufacture date 4 After a slight pause the p...

Page 10: ...ty 6 Slowly open the service valve to allow the system to pressurize The pressure may drop slightly during this process After the valve is fully open open the fixture closest to the Well X1 to begin d...

Page 11: ...ceptance is not exceeded Adjust the precharge as shown on page 12 CAUTION Exceeding Maximum Acceptance will reduce tank life and cause irreparable damage CUT OUT PRESSURE CUT IN PRESSURE 20 25 30 35 4...

Page 12: ...damage or water interruption DANGER Explosion Hazard If the Well X1 has been in service and a change to a higher pre charge is necessary due to a required change in the setting failure to follow instr...

Page 13: ...e runtime indicate an incorrect precharge undersized Well X1 or waterlogged tank Pump continues to run E2 Low Suction Pump operation below 10 psi indicates a low well level well piping leak insufficie...

Page 14: ...Check pump wiring Display will not illuminate 1 Circuit breaker or switch off 2 Faulty or loose wiring 3 Failed control 1 Check breaker and service switch 2 Check line supply wiring 3 Replace Pump wi...

Page 15: ...17 140R517 140R517 140R517 140R517 Pressure sensor tubing 6 9403R197 9403R197 9403R197 9403R197 9403R197 Pressure sensor fitting elbow 7 9401R100 9401R100 9401R100 9401R100 9401R100 Pressure sensor fi...

Page 16: ...NTIES INCLUDINGTHEIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULAR PURPOSE ARE SPECIFICALLY DISCLAIMED Some states do not allow limitations on how long an implied Warranty lasts so the above...

Reviews: