17
Ohms
RANGE AM-160
AM-140
Accuracy
500.00
Ω
0.07%+10d
5.0000K
Ω
50.000K
Ω
500.00K
Ω
0.07%+2d
0.1%+6d
5.0000M
Ω
0.2%+6d 0.4%+6d
50.000M
Ω
2.0%+6d 2.0%+6d
Open Circuit Voltage: < 1.3VDC ( < 3VDC
for 500
Ω
range)
Capacitance
RANGE Accuracy*
50.00nF
0.8% + 3d
500.0nF
0.8% + 3d
5.000
µ
F
1.0% + 3d
50.00
µ
F
2.0% + 3d
500.0
µ
F
3.5% + 5d
9999
µ
F
5.0% + 5d
*Accuracies with film capacitor or better
DC Current
RANGE Accuracy
Burden
Voltage
500.00
µ
A 0.15%+20d 0.15mV/
µ
A
5000.0
µ
A 0.1%+20d
0.15mV/
µ
A
50.000mA 0.15%+10d 3.3mV/mA
500.00mA 0.1%+20d 3.3mV/mA
5.0000A 0.5%+10d 0.03V/A
10.000A* 0.5%+20d 0.03V/A
*10A continuous, 20A for 30 second max
with 5 minutes cool down interval
AC & AC+DC CURRENT
AM-160 AM-140
RANGE
Accuracy
Burden
50Hz -- 60Hz
500.00
µ
A
0.15mV/
µ
A
5000.0
µ
A
0.15mV/
µ
A
50.000mA
3.3mV/mA
500.00mA
3.3mV/mA
5.0000A
0.03V/A
10.000A*
0.5%
+50d
1.0%
+40d
0.03V/A
40Hz – 1kHz
500.00
µ
A
0.15mV/
µ
A
5000.0
µ
A
0.15mV/
µ
A
50.000mA
3.3mV/mA
500.00mA
3.3mV/mA
5.0000A
0.03V/A
10.000A*
0.7%
+50d
1.0%
+40d
0.03V/A
1kHz – 10kHz
500.00
µ
A
0.15mV/
µ
A
5000.0
µ
A
0.15mV/
µ
A
50.000mA
3.3mV/mA
500.00mA
2.0%
+50d
Unspec'
d
3.3mV/mA
5.0000A
10.000A*
Unspec'
d
Unspec'
d
0.03V/A
*10A continuous, 20A for 30 second max
with 5 minutes cool down interval
Crest mode (Instantaneous Peak Hold)
Accuracy: Specified accuracy
±
100 digits
for changes > 0.8ms in duration
DC Loop Current %4--20mA
4mA = 0% (zero)
20mA = 100% (span)
Resolution: 0.01%
Accuracy:
±
25d