9
CAUTION
Using resistance or continuity function in a live circuit will produce false results and
may damage the meter. In many cases the suspected component must be
disconnected from the circuit to obtain an accurate reading.
Capacitance,
Diode test function
Press
SELECT
button momentarily to toggle between Capacitance and
Diode Diode test functions. The new setting will be saved automatically to the
non-volatile memory as power up default.
CAUTION
Discharge capacitors before making any measurement. Large value capacitors should
be discharged through an appropriate resistance load.
Note: Normal forward voltage drop (forward biased) for a good silicon diode is between
0.400V to 0.900V. A reading higher than that indicates a leaky diode (defective). A zero
reading indicates a shorted diode (defective). An OL indicates an open diode
(defective). Reverse the test leads connections (reverse biased) across the diode. The
digital display shows OL if the diode is good. Any other readings indicate the diode is
resistive or shorted (defective).