IEEE 802.3ab Auto-Negotiation support, includes speed, duplex, and flow control
•
IEEE 802.3ab PHY compliance and compatibility with Category-5 twisted pair cabling
•
Implements latest DSP architecture with digital adaptive equalization, echo cancellation, and
crosstalk cancellation to achieve high performance in noisy environments (high electrical/signal
interference impairment)
•
Supports transmit and receive IP, TCP, and UDP checksum offloading capabilities for lower CPU
utilization
•
Supports Transmit TCP segmentation and advanced packet filtering
•
Supports system monitoring with industry standard consoles (SNMP and RMON statistic counters)
•
Supports remote network management capabilities through DMI 2.0 and SNMP software (SDG
3.0, WfM 2.0, and PC2001 compliance)
•
Programmable LED functions for 4 LED support (speed, link, and activity) including blinking
•
Supports integrated magnetics in RJ-45 connector
•
Supports four-pair, 100 ohm, Category 5 UTP (Unshielded Twisted Pair) wiring
Tables 3-21 describes the pin-outs and signals of Gigabit Ethernet port, Ethernet Port 2.
Table 3-21. Ethernet Port 2 Pin/Signal Descriptions (J10)
Pin #
Signal
Description
1
MDI0+
2
MDI0-
Media Dependent Interface [0]
1000BaseT – In MDI configuration, MDI0
±
corresponds to BI_DA
±
, and in
MDI-X configuration, MDI0
±
corresponds to BI_DB
±
.
10/100BaseT – In MDI configuration, MDI0
±
is used for the transmit pair,
and in MDI-X configuration, MDI0
±
is used for the receive pair.
3
MDI1+
6
MDI1-
Media Dependent Interface [1]
1000BaseT – In MDI configuration, MDI1
±
corresponds to BI_DB
±
, and in
MDI-X configuration, MDI1
±
corresponds to BI_DA
±
.
10/100BaseT – In MDI configuration, MDI1
±
is used for the transmit pair,
and in MDI-X configuration, MDI1
±
is used for the receive pair.
4
MDI2+
5
MDI2-
Media Dependent Interface [2]
1000BaseT – In MDI configuration, MDI2
±
corresponds to BI_DC
±
, and in
MDI-X configuration, MDI2
±
corresponds to BI_DD
±
.
10/100BaseT – Unused
7
MDI3+
8
MDI3-
Media Dependent Interface [3]
1000BaseT – In MDI configuration, MDI3
±
corresponds to BI_DC
±
, and in
MDI-X configuration, MDI3
±
corresponds to BI_DD
±
.
10/100BaseT – Unused
9
SPEED_1000
Speed (1000) LED – Indicates transfer rate at 1000Mbps.
10
SPEED_100
Speed (100) LED – Indicates transfer rate at 10Mbps or 100Mbps.
11
LINKLED
Link LED – Indicates Link established between this port and another device
12
ACTLED
Activity LED – Indicates Activity is occurring on the Ethernet link.
13, 14
SHLD
Shields – Connected to center taps of transformer and floating ground while
isolated from board common ground by 1000pf capacitor.
Note
: The shaded area denotes power or ground.
Summary of Contents for LittleBoard 800
Page 1: ...LittleBoard 800 Single Board Computer Reference Manual P N 5001743A Revision A...
Page 26: ...Chapter 2 Product Overview 20 Reference Manual LittleBoard 800...
Page 82: ...Chapter 4 BIOS Setup 76 Reference Manual LittleBoard 800...
Page 84: ...Appendix A Technical Support 78 Reference Manual LittleBoard 800...
Page 90: ...Appendix C Connector Part Numbers 84 Reference Manual LittleBoard 800...
Page 94: ...Index LittleBoard 800 Reference Manual 88...
Page 95: ......
Page 96: ......