Amphenol
PCD Shenzhen
HVSL282 连接器组装规范
Doc. No.: APCD-TD-261
Rev.: B
Page:
7
of
8
Subject: Assembly Instruction for HVSL282 Connector
Eff. Date: 2017-02-28
F-0011-A
4.4
、信号线剥绝缘层。
Signal line strip insulation as shown below
。
4.5
、铆压信号端子,压紧端子后抗拉力
≥57.9N
,压接后尺寸如下图要求。
Crimping signal terminal
,
after crimping
,
the tensile strength
≥57.9N
,
terminal
crimping dimensions as follow
。
4.6
、将信号线插入中间小孔中。如图所示。安装完将线缆轻轻向外拉动,检查端子安装到位。
Insert the signal cable into the small hole in the center of the connector. Gently pull on
the cable to ensure the contact is in place.
4.7
、将压好公针线缆装入胶壳孔内
,
安装完成后将线缆轻轻向外拉动,检查端子安装到位。
Put the male contact’s cable into the housing
as shown below
. Gently pull on the cable
to ensure the contact is in place.
3.5±0.5mm
1.65
±0.06
0.95±0.06