background image

Amphenol

 

PCD Shenzhen

 

HVSL282 连接器组装规范 

 Doc. No.:  APCD-TD-261 

 Rev.: B  

 Page: 

7

 of 

8

  

Subject: Assembly Instruction for HVSL282 Connector  

 Eff. Date: 2017-02-28 

 

F-0011-A 

    4.4

、信号线剥绝缘层。

    

             Signal line strip insulation  as shown below

 

 
 
 
 
 
 
   4.5

、铆压信号端子,压紧端子后抗拉力

≥57.9N

,压接后尺寸如下图要求。

 

Crimping signal terminal

after crimping

the tensile strength 

≥57.9N

terminal      

crimping dimensions as follow

 

 
 
 
 
 
 
 
 
 
 
     4.6

、将信号线插入中间小孔中。如图所示。安装完将线缆轻轻向外拉动,检查端子安装到位。

 

Insert the signal cable into the small hole in the center of the connector. Gently pull on 
the cable to ensure the contact is in place.    
 
 

              
 

                                     

 
 
 
 
 
    4.7

、将压好公针线缆装入胶壳孔内

,

安装完成后将线缆轻轻向外拉动,检查端子安装到位。

 

Put the male contact’s cable into the housing 

as shown below

. Gently pull on the cable 

to ensure the contact is in place.    

 

 
 
 
 
 
 
 

3.5±0.5mm

  

1.65

±0.06

 

 

 

0.95±0.06

 

Summary of Contents for HVSL282

Page 1: ...Page 1 of 8 Subject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A Revision History Date Rev Updated Content Originator Remark 2017 02 28 A First release 2017 05 10 B Prepare...

Page 2: ...ction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 1 SCOPE HVSL This following assembly guidelines apply to the HVSL282 series connector Plug Socket 2 ASSEMBLY INSTRUCTIONS PLUG 2 1 Choose requi...

Page 3: ...Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 3 Strip jacket braiding wire insulation as shown below 2 4 6mm Push the inner ferrule to peeling mouth Shielding wire backward turn wi...

Page 4: ...embly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 6 Crimping terminal after crimping 2 7 Crimping the outer ferrule crimping dimensions as follow Cable Spec 2 5mm 3 0mm 4 0mm A mm...

Page 5: ...8 Put the cable assy into the plug housing 3 TEST INSTRUCTIONS 3 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resista...

Page 6: ...ng the tensile force require and dimensions as follow B A 4 0mm 6 0mm ISO 6722 2006 4 0mm 6 0mm With reference to ISO 6722 2006 the international standard Cable Spec OD mm 3 0mm2 5 0 5 4 4 0mm2 5 4 5...

Page 7: ...9N Crimping signal terminal after crimping the tensile strength 57 9N terminal crimping dimensions as follow 4 6 Insert the signal cable into the small hole in the center of the connector Gently pull...

Page 8: ...ject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 5 TEST INSTRUCTIONS 5 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5...