background image

Amphenol

 

PCD Shenzhen

 

HVSL282 连接器组装规范 

 Doc. No.:  APCD-TD-261 

 Rev.: B  

 Page: 

5

 of 

8

  

Subject: Assembly Instruction for HVSL282 Connector  

 Eff. Date: 2017-02-28 

 

F-0011-A 

        2.8

、将线缆组件如下所示,插入插头外壳内。

 

                 Put the cable assy. into the plug housing

 

 
 
 
 
 

 

                                    

 
 
 

 

 
 

 

3.  TEST  INSTRUCTIONS 

 

 

3.1

  100%

耐压、绝缘测试。

    

100%High-voltage

insulation test

 

   

 

AC3000V

10S

,漏电流

≤5mA. DC 500V

10S

,绝缘电阻

≥100MΩ 

     AC3000V

10S

Leakage current≤5mA. DC 500V

10S

Insulation resistance≥100MΩ 

 

3.2

  100% 

导通测试。

    

            100% Continuity test

 

 

3.3

  100% IPX7 

防水测试。

   

            100% IPX7 Water proof test 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

组装完成

 

Final assembly

 

楔台可见。

 

The latch stops 
should be visible. 

卡槽位相对应。

 

.

 Corresponding 

card slot.

 

Summary of Contents for HVSL282

Page 1: ...Page 1 of 8 Subject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A Revision History Date Rev Updated Content Originator Remark 2017 02 28 A First release 2017 05 10 B Prepare...

Page 2: ...ction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 1 SCOPE HVSL This following assembly guidelines apply to the HVSL282 series connector Plug Socket 2 ASSEMBLY INSTRUCTIONS PLUG 2 1 Choose requi...

Page 3: ...Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 3 Strip jacket braiding wire insulation as shown below 2 4 6mm Push the inner ferrule to peeling mouth Shielding wire backward turn wi...

Page 4: ...embly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 6 Crimping terminal after crimping 2 7 Crimping the outer ferrule crimping dimensions as follow Cable Spec 2 5mm 3 0mm 4 0mm A mm...

Page 5: ...8 Put the cable assy into the plug housing 3 TEST INSTRUCTIONS 3 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resista...

Page 6: ...ng the tensile force require and dimensions as follow B A 4 0mm 6 0mm ISO 6722 2006 4 0mm 6 0mm With reference to ISO 6722 2006 the international standard Cable Spec OD mm 3 0mm2 5 0 5 4 4 0mm2 5 4 5...

Page 7: ...9N Crimping signal terminal after crimping the tensile strength 57 9N terminal crimping dimensions as follow 4 6 Insert the signal cable into the small hole in the center of the connector Gently pull...

Page 8: ...ject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 5 TEST INSTRUCTIONS 5 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5...