HVSL282 连接器组装规范 

 Doc. No.:  APCD-TD-261 

 Rev.: B  

 Page: 

3

 of 

8

  

Subject: Assembly Instruction for HVSL282 Connector  

 Eff. Date: 2017-02-28 

 

F-0011-A 

2.3

 

按尺寸剥开线缆护套、屏蔽层、绝缘层

.    

Strip jacket

braiding wire

insulation  as shown below

 

                                                          
 
 
 
 
 
 
 
 
 
          
 
 
                     
 

2.4

 

将内金属环推到剥皮口处,屏蔽铜丝全部后翻,在屏蔽上包一层

6mm

铜箔。

 

             

Push the inner ferrule to peeling mouth

Shielding wire backward turn

with 8mm 

copper foil bag tight

 

 

 

        

        

 

 

2.5

 

将外金属环穿套到铜箔上。

                                                                                                                        

   

Assemble the outer-ferrule on the copper foil

 

 

 

 

 

 

 

 

 

6mm 

Summary of Contents for HVSL282

Page 1: ...Page 1 of 8 Subject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A Revision History Date Rev Updated Content Originator Remark 2017 02 28 A First release 2017 05 10 B Prepare...

Page 2: ...ction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 1 SCOPE HVSL This following assembly guidelines apply to the HVSL282 series connector Plug Socket 2 ASSEMBLY INSTRUCTIONS PLUG 2 1 Choose requi...

Page 3: ...Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 3 Strip jacket braiding wire insulation as shown below 2 4 6mm Push the inner ferrule to peeling mouth Shielding wire backward turn wi...

Page 4: ...embly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 6 Crimping terminal after crimping 2 7 Crimping the outer ferrule crimping dimensions as follow Cable Spec 2 5mm 3 0mm 4 0mm A mm...

Page 5: ...8 Put the cable assy into the plug housing 3 TEST INSTRUCTIONS 3 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resista...

Page 6: ...ng the tensile force require and dimensions as follow B A 4 0mm 6 0mm ISO 6722 2006 4 0mm 6 0mm With reference to ISO 6722 2006 the international standard Cable Spec OD mm 3 0mm2 5 0 5 4 4 0mm2 5 4 5...

Page 7: ...9N Crimping signal terminal after crimping the tensile strength 57 9N terminal crimping dimensions as follow 4 6 Insert the signal cable into the small hole in the center of the connector Gently pull...

Page 8: ...ject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 5 TEST INSTRUCTIONS 5 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5...