background image

Amphenol

 

PCD Shenzhen

 

HVSL282 连接器组装规范 

 Doc. No.:  APCD-TD-261 

 Rev.: B  

 Page: 

1

 of 

8

  

Subject: Assembly Instruction for HVSL282 Connector  

 Eff. Date: 2017-02-28 

 

F-0011-A 

修订履历

 Revision History 

修订日期

 

Date 

版本

 

Rev. 

修订内容

 

Updated Content 

作者

 

Originator 

备注

 

Remark 

2017-02-28 

First release 

杨圣祥

 

 

2017-05-10 

产品部分结构变更

 

    

杨圣祥

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

制作

Prepared By:  

杨圣祥

                

审核

Checked By:                             

批准

 Approved By: 

日期

Date:   2017-05-10                    

日期

Date:                                          

日期

Date:                        

                  

Summary of Contents for HVSL282

Page 1: ...Page 1 of 8 Subject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A Revision History Date Rev Updated Content Originator Remark 2017 02 28 A First release 2017 05 10 B Prepare...

Page 2: ...ction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 1 SCOPE HVSL This following assembly guidelines apply to the HVSL282 series connector Plug Socket 2 ASSEMBLY INSTRUCTIONS PLUG 2 1 Choose requi...

Page 3: ...Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 3 Strip jacket braiding wire insulation as shown below 2 4 6mm Push the inner ferrule to peeling mouth Shielding wire backward turn wi...

Page 4: ...embly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 6 Crimping terminal after crimping 2 7 Crimping the outer ferrule crimping dimensions as follow Cable Spec 2 5mm 3 0mm 4 0mm A mm...

Page 5: ...8 Put the cable assy into the plug housing 3 TEST INSTRUCTIONS 3 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resista...

Page 6: ...ng the tensile force require and dimensions as follow B A 4 0mm 6 0mm ISO 6722 2006 4 0mm 6 0mm With reference to ISO 6722 2006 the international standard Cable Spec OD mm 3 0mm2 5 0 5 4 4 0mm2 5 4 5...

Page 7: ...9N Crimping signal terminal after crimping the tensile strength 57 9N terminal crimping dimensions as follow 4 6 Insert the signal cable into the small hole in the center of the connector Gently pull...

Page 8: ...ject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 5 TEST INSTRUCTIONS 5 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5...