 Doc. No.:  APCD-TD-261 

 Rev.: B  

 Page: 

6

 of 

8

  

Subject: Assembly Instruction for HVSL282 Connector  

 Eff. Date: 2017-02-28 

 

F-0011-A 

4.  ASSEMBLY INSTRUCTIONS

(Socket)

                                  

 

  4.1

、选择符合以下要求的屏蔽线缆或非屏蔽线

.   

     Choose required shielding or 

shielding wire

 . 

 
 
 
 
 
 

 

 

 

     4.2

、按尺寸剥开电源线缆护套、绝缘层。

    

              Strip jacket

insulation for power cable as shown below

  

 

 
 
 
 

 

                                       

 
 
 
 
 

     4.3

、铆压电源线端子,压紧端子后抗拉力不小于下表中数值,压接后尺寸如下图要求。

 

              Crimping power wire terminal

after crimping

the tensile force require and dimensions 

 as follow

 

 

 
 

 

 

        
                      

 

 
 
 
 
 
 
 
 
 

B

 

A

 

4.0mm²/6.0mm²

依照

ISO 6722:2006

 

国际汽车电线标准 

4.0mm²/6.0mm²

 

With reference to ISO 

6722:2006 the international standard 

线缆规格

Cable Spec

直径

 OD

mm

3.0mm2

5.0-5.4

4.0mm2

5.4-5.8

Shielding Cable

 

Unscreened Shielding Cable

 

   信号线规格

Signal cable Spec

直径

 OD

mm

0.5mm2

1.6-1.8

0.75mm2

2.1-2.7

6.0±0.5mm

2mm(ref)

Insulation

Cable

Heat shrink tubing

6.0±0.5mm

2mm(ref)

20mm(ref)

Insulation

shielding cut off

Cable

Shielding Cable

 

Unscreened Shielding Cable

 

Cable spec

线缆规格

    A (mm)

B (mm)

3.0mm2

 2.0±0.06

4.0mm2

2.3±0.06
3.2±0.06

 3.2±0.06

Summary of Contents for HVSL282

Page 1: ...Page 1 of 8 Subject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A Revision History Date Rev Updated Content Originator Remark 2017 02 28 A First release 2017 05 10 B Prepare...

Page 2: ...ction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 1 SCOPE HVSL This following assembly guidelines apply to the HVSL282 series connector Plug Socket 2 ASSEMBLY INSTRUCTIONS PLUG 2 1 Choose requi...

Page 3: ...Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 3 Strip jacket braiding wire insulation as shown below 2 4 6mm Push the inner ferrule to peeling mouth Shielding wire backward turn wi...

Page 4: ...embly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 2 6 Crimping terminal after crimping 2 7 Crimping the outer ferrule crimping dimensions as follow Cable Spec 2 5mm 3 0mm 4 0mm A mm...

Page 5: ...8 Put the cable assy into the plug housing 3 TEST INSTRUCTIONS 3 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resista...

Page 6: ...ng the tensile force require and dimensions as follow B A 4 0mm 6 0mm ISO 6722 2006 4 0mm 6 0mm With reference to ISO 6722 2006 the international standard Cable Spec OD mm 3 0mm2 5 0 5 4 4 0mm2 5 4 5...

Page 7: ...9N Crimping signal terminal after crimping the tensile strength 57 9N terminal crimping dimensions as follow 4 6 Insert the signal cable into the small hole in the center of the connector Gently pull...

Page 8: ...ject Assembly Instruction for HVSL282 Connector Eff Date 2017 02 28 F 0011 A 5 TEST INSTRUCTIONS 5 1 100 100 High voltage insulation test AC3000V 10S 5mA DC 500V 10S 100M AC3000V 10S Leakage current 5...

Reviews: