AMPEON AMP-Series
http://www.ampeon.cn
19
personnel dissipates. The parameters must be set up by special personnel. The
operator is prohibited to change the setting, or trouble may happen.
d) This machine has the function of automatic adjustment to the“reset delay” time,
that is to say, the function of automatic adjustment of maintenance time after the
action of diverter. In case of special big metal substance, the corresponding reset
delay time will increase.
e) In case of the continuous action of metal detector and if it is necessary to
change the setting of the sensitivity, please continuously push the ’parameter setting’
button and transform the function to sensitivity adjustment mode and decrease the
sensitivity parameter.
f) APU-02 is a computer unit, if strong magnetic interference or other factor
happened and caused the parameter unit abnormal, please shut down the main power
supply for one minute and then reenergize and recheck every parameter.
2. Fire alarm simulation test
a. There is an active window on the pipe beside the spark diverter. Shine the
spark sensor through the small window and it will be OK if the controller can carry
out normal action.
(
The tungsten filament of the torch is a hot body and includes
infrared ray
)
During action, it alarms with sound and light, so it is necessary to turn
off the alarm manually.
b. During the normal use, if fire alarm happens, operation cannot be started until
the cause is found out. Occasionally although the spark is small and can be out by
itself, we should also stop for not less than half an hour and we cannot start until it is
inspected and the safety can be assured.
▲
Caution!
a. The spark alarm function should be checked regularly with simulation test to
assure that they are in the good working status. It is suggested that the test be carried
out at least once every two weeks.
b. The dust and cloth waste on the surface of lens in spark detector must be
regularly checked and cleaned.
3. Metal diverting function test and adjustment
In the meantime of metal diverting function test, it is necessary to do the setting
of parameters such as sensitivity, action delay and reset delay.