background image

 

 

Gas Release Panel Short Form Installation Guide 

Item Numbers: 2983-0304 

 

“ Our aim is to provide 

 

Consistently Excellent Service ’

  in the eyes of our customers ”

 

 

MAN1807 

Page 2 of 3 

Website: www.ampac.net 

 

+

A

A

B

B

C NO NO

C NC

NO

C NC

NO

C NC

NO C NC

NO C NC

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

SIL

AL FLT RST +

-

-

ESU

ZONE 1

ZONE 2

ZONE 3

SOUND
    1A

SOUND
    1B

  SOUND
2nd STAGE

 MODE
SELECT

 MANUAL
RELEASE

ABORT

HOLD

    LOW
PRESSURE

 FLOW
SWITCH

REMOTE INPUTS

REMOTE STATUS UNIT

EXTRACT

1st STAGE

2nd STAGE

FAULT

LOCAL FIRE

 FIRE

EXTINGUISH
  OUTPUT

ACCESS LEVEL
   3 SWITCH

RLY2

RLY3

RLY4

RLY5

RLY6

RLY1

R

el

ay

 6 ene

rg

is

e

s o

n ac

tiv

a

tion

 o

f any

 z

o

ne f
ire al
ar

m

or

 pr
es

sing

 pa

nel
 s

oun
d al
ar

m

 pu

shb

ut

to

n

R

el

ay

 5 ene

rg

is

e

s o

n ac

tiv

a

tion

 o

f any

 z

o

ne f
ire al
ar

m

or

 pr
es

sing

 pa

nel
 s

oun
d al
ar

m

 pu

shb

ut

to

n

R

el

ay

 4 i
s no
rm

al

ly

 e

ner
gi

sed

 a

nd de

-e

ner
gi

ses

 up

on

an

y f

au

lt c

ond
itio

n

R

el

ay

 3 ene

rg

is

e

s w

he

n t

h

e pan

el

 ha
s ent
er

ed

 ac

tiv

at

ed

con

di

tion,
 i.e.

 the

 e

xti

ng

ui

sher
 r

e

le

as

e t

im

er

 has

 s

tar

ted

R

el

ay

 2 ene

rg

is

e

s o

n ac

tiv

a

tion

 o

f a z
on

e t

ha

t i

s p

ar

t of

 the

 e

xti

ng

ui

sher

rel

eas
e

 c

irc

ui

try

, o

r pr

es

sin

th

e p
ane
l s

ou

nd 
al

ar

m

 p

us

h

but
ton

R

el

ay

 1 

ene
rg

is

e

s w

he

an 
A

cc

es

s Le

vel

 2

 u

ser

 s

el

e

cts

 S

tar

t

E

xtr

ac

t F

an

 a

fter

 flood
in

g t

im

e has

 el

ap

sed (
w

ithou
t a r
e

set

)

MON5

PRESS
  SW

S

OL
E

N

OI

D

SYSTEM LINE
TERMINATOR

E

X

T

ING
UI

S

HA
NT

MON6

FLOW
  SW

RSU n (8 max)

RSU 1

2

2

RS485

R

ES
ET
 S

W

+2
4

V

0V

F

AU
LT

 SW

S

O

UND

 A

LA

RM
 S

W

S

IL

EN
C

E

 AL
AR
M

 S

W

2

2

2

2

2

2

2

2

2

MON4

MON3

MON2

MON1

MON6

MON5

FLOW
SW

PRESSURE
SW

470R

470R

6K8 EOL

6K8 EOL

Z2

Z3

S1B

S2

S1A

+

+

+

6K8 EOL

POLARISED
SOUNDER

POLARISED
SOUNDER

POLARISED
SOUNDER

     DO NOT SPUR

WIRING NOT MONITORED

Z1

6K8 EOL

SMOKE OR
HEAT DETECTOR

SMOKE OR
HEAT DETECTOR

     DO NOT SPUR

WIRING NOT MONITORED

2

2

2

2

ESU 1

ESU n (8 MAX)

RLY1

MON1

RLY6

MON6

S1B

S2

S1A

Z1

Z3

NOTES: See Technical Specifications overleaf for further details.

Detector Circuits 1 to 3.

Sounder Circuits. Two x 1st stage; One x 2nd stage.

Monitored Input Circuits 1 to 6.

Relay Outputs 1 to 6.

Remote Inputs: +/- Remote Supply; SIL - Silence Alarm; AL - Sound Alarm; FLT - Fault; RST - Reset.

GAS RELEASE PANEL MAIN CONTROL BOARD