![Amit IWP87DAM-07151 User Manual Download Page 68](http://html1.mh-extra.com/html/amit/iwp87dam-07151/iwp87dam-07151_user-manual_2933418068.webp)
PoE
AP
Router
68
(7W),
802.3af(15.4W),
802.3at(30W),
or
Manual
.
If
you
select
Manaual
,
you
have
to
enter
the
power
limit.
Value
Range
:
1
~
30
Watts.
Low
Priority
PD
Knockoff
Highest
by
default
Specify
the
Port
Priority. It
can
be
Highest,
High,
or
Low
.
Whenever
there
is
a
shortage
of
total
power
budget,
the
port
with
lowest
priority
will
be
disabled
automatically
to
provide
required
power
to
the
ports
with
higher
priority.
If
there
are
more
than
one
ports
with
the
same
lowest
priority,
the
port
number
decide
it,
Port
1
>
Port
2
>
Port
3
>
Port
4,
it
means
Port
4
has
the
lowest
priority
on
such
case..
PD
Ping
Check
The
box
is
unchecked
(
Disable
)
by
default
Check
the
Enable
box
to
activate PD
Ping
Check
function.
In
addition
to
enable
the
function,
you
have
to
specify
a
timeout
value
for
timeout
check.
Value
Range
:
10
~
300
seconds.
PD
No
‐
response
Action
No
Action
by
default
Specify
the
the
action
to
take
when
the
PD
doesn’t
reply
the
Ping
check
activity.
(PD
No
‐
response).
It
could
be
No
Action
or
Power
off/on
.
Select
Power
off/on
to
restart
the
PD
device,
if
required.
PD
Power
Overload
No
Action
by
default
Specify
the
the
action
to
take
when
the
PD
Power
overflow
occurs
for
a
certain
port.
It
can
be
No
Action
or
Power
Long
Time
Off/On
.
If
the
Power
overload
occurs
(PD
consumes
more
power
than
the
value
specified
in
the
Power
Limit
setting),
the
PSE
function
for
the
PoE
port
will
be
disabled
for
30
minutes.
That
is,
PD
device
will
be
powered
OFF
for
a
long
time,
and
then
after
30minutes,
it
will
be
powered
ON
again.
If
you
encountered
such
situation,
please
check
if
the
Power
Limit
setting
is
properly,
or
the
PD
device
always
consumes
too
much
power.
Time
Schedule
(0)Always
by
default
Apply
Time
Schedule
to
control
the
power
ON/OFF
schedule
of
the connected
PD
,
otherwise
leave
it
as
(0)
Always
.
If
the
dropdown
list
is
empty,
ensure
Time
Schedule
is
pre
‐
configured.
Refer
to
Object
Definition
>
Scheduling
>
Configuration
tab.
Save
N/A
Click
the
Save
button
to
save
the
configuration.
Note:
If
the
sum
of
Power
Limits
for
all
ports
is
greater
than
the
specified
Power
Budget,
the
port
with
lowest
priority
will
be
disabled
to
make
the
PSE
work
normally.