background image

  

   

www.amico.com 

   

 7

Check 

Valve 

1” 

        

VV-CHK3-EXT10

Check 

Valve 

1-1/2” 

       

VV-CHK3-EXT15

Check 

Valve 

2” 

        

VV-CHK3-EXT20

Relief Valve Pipe Away Adapter ½” NPT (NFPA)   

 

 

 

M-X-PIPEAWAY-05

Relief 

Valve 

(NFPA) 

       

M-X-MAN-72W-075

Relief 

Valve 

(CSA)        

M2-X-MAN-73-075

Optional Check and Relief Valves (to be ordered separately):

Model Number:

 M-FILL-OXY-LP-S

Model numbers also available: 

M-FILL-OXY-LP2S

  

 

Emergency low pressure oxygen inlet station 2” surface mounted 

 

M-FILL-OXY-LP2

  

 

Emergency low pressure oxygen inlet station 2” recessed mounted 

M-FILL-OXY-S  

 

 

Emergency high pressure oxygen inlet station 1” surface mounted 

 

M-FILL-OXY

    

 

Emergency high pressure oxygen inlet station 1” recessed mounted

Schematic Drawing - Surface Mount

26"

[660]

2" Type "K" 

Copper outlet pipes

Inlet Oxygen

connection

2" NPT

Shutoff

Valve

8"

[203]

17"

[431]

18"

[457]

Typical Piping

Turn Down 

and Screen

Emergency Low 

Pressure Oxygen 

Inlet Box

Main Oxygen 

Supply

Main Line 

Shutoff Valve

Check Valve 

Pressure 

Switch

Relief Valve 

75 PSIG

Shutoff 

Valve

  11 

[280]

Inlet 

Oxygen 

connection 

1” NPT

1” Type “K” 

Copper Outlet Pipes

  16 

[406]

[228.6]

    6 

[152]

  12 

[305]

Summary of Contents for M-FILL-OXY-LP

Page 1: ...Operation Maintenance Installation Manual Emergency Oxygen Inlet Station Low Pressure 1 Recessed Mount Model M FILL OXY LP Surface Mount Model M FILL OXY LP S w w w a m i c o c o m...

Page 2: ...edical Facility Responsibility 3 Installation of Emergency Oxygen Inlet Station 4 Operating Instructions 4 Repair and Replacement Parts List 5 Schematic Drawings 6 7 Optional Check and Relief Valves P...

Page 3: ...rovided with a plug to prevent entry of foreign matter into the oxygen system when not in use Amico Emergency Oxygen Inlet Stations will perform in conformity with the descriptions contained in this m...

Page 4: ...em for leaks as per appropriate standards To Operate 1 Ensure that the isolation valve is closed 2 Open the threaded connection 3 Connect a pigtail to the oxygen threaded connection 4 Check the inlet...

Page 5: ...lve seats and O rings 2 V X VLV HAND M Valve handle sleeve for 1 3 V X GAUGE 100 Gauge 100 psi 690 kPa 1 8 NPT 4 M X OXF PLUG LP 1 NPT hex head plug 5 V X BOX PLUG Box plug for oxygen inlet station Bo...

Page 6: ...Connect to pipeline Inlet Oxygen connection 1 NPT Shutoff Valve Provision for Padlock 7 1 4 184 Main Line Shutoff Valve Check Valve 2 required Relief Valve 75 PSIG Turn Down and Screen Main Oxygen Sup...

Page 7: ...XY LP2 Emergency low pressure oxygen inlet station 2 recessed mounted M FILL OXY S Emergency high pressure oxygen inlet station 1 surface mounted M FILL OXY Emergency high pressure oxygen inlet statio...

Page 8: ...co com 85 Fulton Way Richmond Hill Ontario L4B 2N4 Canada Toll Free Tel 1 877 462 6426 Toll Free Fax 1 866 440 4986 Tel 905 764 0800 Fax 905 764 0862 Email info amico com APE OM INSTAL EOIS LP 2IN 01...

Reviews: