SUCCESSFUL SEAL INSTALLATION
1.
Read entire installation procedure
before beginning installation.
2.
Handle components carefully.
Careless handling of the critical seal components
may result in chipping, cracking or breakage.
3.
Do not touch sealing areas.
The sealing faces, O-rings, wedges, and bellows
must kept perfectly clean. Even a fingerprint can cause a seal to leak.
Primary and secondary sealing areas must be kept clean and undamaged to ensure a
proper seal. Rubber gaskets tear easily when handled carelessly.
4. Make sure that the
shaft or sleeve is free of burrs, nicks. grooves, and sharp edges.
5.
Bleed all trapped gases from the seal cavity before start-up
, otherwise the seal
cavity may vapor lock and burn the seal.
6.
All valves must be open on the suction side of the pump
so that the seal is
assured of a positive flow of liquid at all times. Failure to do so will also cause the seal
to burn.
21 of 34